Troubleshooting
Problem Probable
cause(s)
Remedy
Tripix Power and fixture are
completely dead
No power to Tripix Power
Check power and connections.
Primary fuse blown (located
in fuse holder on front panel
of Tripix Power)
Isolate fixture from power.
Check fuse and replace.
One or more fixtures
respond incorrectly to
control or do not respond at
all
Fault on DMX link
Inspect connections and cables.
Correct poor connections.
Repair or replace damaged
cables.
Incorrect DMX addressing
Check Tripix fixture is set to
correct DMX mode.
Check Tripix fixture’s DMX
address and channels assigned
to it at controller.
Other device on DMX link
defective
Bypass devices on DMX link
until the faulty device has been
identified.
Have faulty device tested and
serviced by Martin service
technician or device supplier.
Wrong fixture configuration
Check the fixture configuration
and if necessary use MUM to
reconfigure.
LEDs cut out intermittently
Tripix Power is too hot
Ensure free airflow around Tripix
Power.
Clean the Tripix Power.
Check that ambient temperature
does not exceed maximum
permitted level.
Contact Martin for service.