• ©2020 EVO-LITE, LLC • 6240 W 54TH AVE., ARVADA, CO 80002 • V2–3220
BEST PRACTICES
// LEDs are bright. Do not look directly at lighted sheet.
// To avoid visible brightness variances due to voltage drop, the
total distance from power source input to the farthest end of any
interconnected sheet should not exceed 6.5 feet (2 meters). See
power input section on page 3.
// Dry fit the Light Sheets and their connection wires before installing
them permanently to a substrate. Always test operation before
installing the translucent (forward facing) material.
// Horizontal applications require a completely flat mounting surface.
Any deviations could result in the forward facing material(s) being
damaged.
// Never slide heavy material over the bumpers, this can cause damage
to the Light Sheet. If a forward facing material needs to be removed,
lift the material, do not drag as this can damage the Light Sheet.
// Do not fold Light Sheets back-to-back.
// Avoid installing where subject to continuous flexing.
// Application specific installation guides are available upon request.
For the latest product updates, specifications, troubleshooting, product handling, installation & integration advisories, visit www.evo-lite.com.
CONTENTS
Each Auragami
®
Light Sheet package includes one sheet (A), two short wires (B),
two long wires (C) and eight bumpers (D).
SAFETY INFORMATION
Read all installation instructions before beginning.
// To reduce the risk of fire, electric shock or injury to persons, pay close attention to this manual and stay within its guidelines when using this
product. Save these instructions for future use.
READ AND FOLLOW THE PRODUCT HANDLING, INSTALLATION & INTEGRATION ADVISORY
ON PAGE 4. DISCONNECT POWER AT THE SOURCE BEFORE CUTTING OR ALTERING THE LIGHT SHEET(S) IN ANY WAY.
DO NOT CONNECT
LIGHT SHEETS TO AC CURRENT. USE ONLY WITH 24V DC INPUT POWER.
// Products should be installed in accordance with these instructions, current local/regional electrical codes and/or the current National Electric
Code (NEC).
// Use only with UL Listed or UL Recognized Class 2, Limited Power Source (LPS) or LVLE (Low Voltage Limited Energy) power supplies. Provide the
appropriate number of 24V Class 2 circuits for your layout. Do not exceed the maximum load limit of any power supply per the manufacturer’s
recommendations.
// To retain Class 2 compliance per UL regulations, do not interconnect more than eight full Light Sheets (88 watts total) in any configuration.
Each Light Sheet consumes 11 watts of power (0.46 A at 24V DC). In order to connect eight Light Sheets, confirm that the combined power
consumption is never more than 88 watts total. The Light Sheet’s FPC (Flexible Printed Circuit) design and integrated connection blocks have a
96 W / 4 A at 24V DC capacity. Do not exceed the capacity of the FPC and connections blocks in any configuration.
// This product is rated IP65 and can be used in wet locations, but not where water may accumulate.
// When using any type of mechanical fastener, make sure the fastener head does not penetrate the Auragami Light Sheet. Any penetrations of the
Light Sheet must be made inside the smaller of the two concentric circles marked on the sheet.
PART
DESCRIPTION
QTY
A
Auragami
®
Light Sheet (19.80” x 9.25” / 503.5 mm x 235 mm) with
3M
®
adhesive backing and 12 integrated connection blocks
1
PART
ACCESSORY PACK (INCLUDED: AG1-24-RGBW-AP)
QTY
B
20 AWG short sheet-to-sheet connection wires 3.26” (83 mm)
2
C
20 AWG long sheet-to-sheet connection wires 5.86” (149 mm)
2
D
Protective bumpers with silicone adhesive backing
8
A
B
C
D
AURAGAMI
®
LIGHT SHEET
SHORT SHEET-TO-SHEET
CONNECTION WIRES
LONG SHEET-TO-SHEET
CONNECTION WIRES
* Not to Scale
PROFILES
Each bumper
can support
up to 400 lbs
(199kg)
Bumper with silicone
adhesive backing
Integrated 5-pin connection
block (TYP. of 12)
RGBW LIGHT SHEETS
0.35” (9mm)
(when bearing
weight)
including Light
Sheet thickness
3/8” Nominal
0.25”
(6.5mm)
including
Light Sheet
thickness
1/4” Nominal
BEST PRACTICES
Do not set anything on top of Light Sheets (i.e. tools, mugs, etc.).
Do not set Light Sheets on the floor where they could be stepped
upon or where anything can be dragged or set upon them. Light
Sheets can be damaged unless properly handled.
Due to possible unforeseen issues with shipping and handling,
we advise that all Light Sheets be inspected at time of delivery
and dry-fit tested for proper illumination prior to mounting and
again before the forward facing material is installed.
For troubleshooting guidance, please visit www.evo-lite.com
FLEXIBLE LED LIGHT SHEET | RGBW
ITEM #: AG1-24-RGBW SERIES (RED, GREEN, BLUE, WHITE)
INSTRUCTION MANUAL
BACKLIGHTING // LED SHEETS // AURAGAMI
®
// RGBW
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTIFICATION
PHYSICAL
Cut/Fold Line
Spacing
0.99” (25.18 mm) short axis / 0.925” (23.5 mm) long axis
Coverage
1.27 ft
2
0(.118 m
2
) per sheet / up to 10.18 ft
2
(0.94 m
2
)
per Class 2 guidelines
Operating Temp.
-30˚C (-22˚F) ~ +50 °C (+122 °F)
POWER & CONTROLS
Compatible with full range (100% - 0%), flicker-free power and control components.
Please contact Evo-Lite for optimal solutions to fit your requirements.
ELECTRICAL
Input Voltage
24 Volt DC - Constant Voltage
Input Power
11 W per sheet
Connectivity
Up to eight sheets via integrated connection blocks (not to exceed 88 W)
Certification
UL Listed (E495221), CE Compliant (EMC and LVD), RoHS Certified, IP65
SPECIFICATIONS
24V
IP65
RoHS
C O M P L I A N T
DIMMABLE
+
−
83 mm (3.26”)
PROTECTIVE BUMPERS
9 mm
(0.35”)
12.8 mm (0.50”)