LIGHT SHEET ORIENTATION

RGBW and Tunable White Auragami Light Sheets have arrows printed on them. These 

arrows mark the direction and orientation that all sheets must be installed. 

When mounting 

multiple sheets, it is important that the arrows on each sheet line up and point the same 

direction.

 These arrows help maintain equal LED spacing. If the arrows are not aligned, you 

may experience color shifts or hot spots. See Figure 8.

MOUNTING LIGHT SHEETS

Various mounting methods may be used to secure the Light Sheets to the mounting surface after the dry-fit and operation tests are complete. 

Use the appropriate method or combination of methods depending on the type of mounting surface and its orientation. Mechanical fastening is 

recommended in addition to the adhesive back.

Mechanical Fasteners: Any penetrations through the Light Sheet must be made inside the concentric circles marked on the sheet. The smaller 

diameter circle on the Light Sheet indicates the maximum diameter of screw or other fastener that can be used without causing damage to the 

Light Sheet’s power distribution grid. The larger diameter circle is the maximum diameter of the screw head that can be used without causing 

damage. See Figure 9. For suspended applications, use mechanical fasteners with an appropriate spacing to avoid sagging. Use pan head, domed, 

or round head screws – not tapered screws (like wood or drywall screws) nor self-tapping screws – and never screw the fastener so much that it 

deforms the Light Sheet. See Figure 10. 

Re-test function before installing the translucent (forward facing) material. 

0.24”

(6 mm) 

0.12”

(3 mm) 

Figure 9

Figure 8

Figure 10 

POWER INPUT 

Use only with Class 2 power units. To avoid visible brightness variances due to voltage drop, the total distance should not exceed 6.5 ft (2 meters) 

from the Light Sheet’s power supply input to the farthest end of any interconnected sheet. If this distance exceeds 6.5 ft (2 meters), splice an 

additional high count multi-strand lead wire (that is the appropriate gauge for the load and distance) to the power input wire and connect this lead 

to a sheet that is centrally located within the interconnected sheets. Alternatively, split the length in two and power each with its own power supply, 

making sure the two sections are not connected electrically (see Figure 6).

Use the power lead (E) to route power from the power supply to a single Light Sheet or a set of up to eight Light Sheets. Use

 Wago connectors (F) 

in place of wire nuts, for a secure connection of wires of the same polarity (see figure 7). Do not exceed the 4 A maximum load capacity of a 

connection block in any configuration nor interconnect more than eight sheets (88 W total). If any Light Sheet fails to light, check that the sheet-to-

sheet connection wires are fully connected into the 5-pin connection blocks. If the whole layout fails to light, check polarity at the power supply, 

proper connection at the splicing connectors, and supply power at the source.

Light  Sheets  are  dimmable,  compatible  with  full-range  (100%  -  0%),  flicker-free  power  and  control  components.  Barrel  connectivity  options/

accessories are sold separately for use with barrel connected plug-in power supplies. Contact an Evo-Lite Systems Integration Specialist for optimal 

power and control solutions to fit the project needs.

Power Input Kit, SKU: AG1-24-RGBW-PIK (sold separately):

Includes one 48” (1219.2 mm) 20 AWG 5-conductor power lead 

wire with stripped & tinned ends (E), five Wago connectors (F) (see 

Figure 7) and four cable management clips (G) (see Figure 3).

Figure 7

E

F

G

POWER INPUT CABLE

WAGO CONNECTORS

* Not to Scale

+

Multi-Channel Control Component

(24V DC Output sold separately)

B

G

R

W

x5

Note: The black wire is positive (+) 

and the other colored wires (RGBW)

are signal (-) control wires.

F

E

G

––

One power input is required for each Class 2 circuit

Figure 6

221

221

221

221

221

CABLE MANAGEMENT CLIPS

Summary of Contents for Auragami AG1-24-RGBW Series

Page 1: ... more than 88 watts total The Light Sheet s FPC Flexible Printed Circuit design and integrated connection blocks have a 96 W 4 A at 24V DC capacity Do not exceed the capacity of the FPC and connections blocks in any configuration This product is rated IP65 and can be used in wet locations but not where water may accumulate When using any type of mechanical fastener make sure the fastener head does...

Page 2: ...shaped as shown in Figure 2 prior to pushing into connection blocks Best practices include using two sheet to sheet connection wires for all adjacent Light Sheets in each Class 2 circuit to minimize voltage drop Dry fit test for proper illumination prior to mounting Light Sheets to the mounting surface and again before the forward facing material is installed USING AURAGAMI ACCESSORIES Figure 1 Fi...

Page 3: ...eed 6 5 ft 2 meters from the Light Sheet s power supply input to the farthest end of any interconnected sheet If this distance exceeds 6 5 ft 2 meters splice an additional high count multi strand lead wire that is the appropriate gauge for the load and distance to the power input wire and connect this lead to a sheet that is centrally located within the interconnected sheets Alternatively split th...

Page 4: ...unique challenges we hope by making you aware of the following handling and installation guidelines you are empowered with knowledge for a successful installation As always your Evo Lite Systems Integration Specialist or any of our staff are ready to assist you with any questions that arise during your installation FOLDING MINIMUM RADIUS There is no minimum bending radius for Auragami Light Sheets...