AURAGAMI

®

 DRY FITTING, CUTTING* AND FOLDING

 

Dry fit the sheets and connection wires before mounting the Light Sheets to the substrate. 

Always test function before installing the translucent (forward 

facing) material. 

To make a fold in an Auragami Light Sheet, bend the sheet along one of the dotted lines marked on the sheet, then crease along this line, then relax the 

fold into a 90° (or other desired) angle. 

Be careful about folding where an LED is attached to the sheet since LEDs can break if forced over an edge. Do not 

repeatedly fold and unfold along the same line as this will weaken the flexible PCB. Do not fold a Light Sheet back onto itself, however two separate Light 

Sheets can be attached back-to-back.

To make a cut in an Auragami Light Sheet, use shears, scissors, a utility knife and/or a precision/craft knife. 

Cut  on  horizontal  and/or  vertical  lines.  Deviating  from  the  lines  could  cut  off  power  to  one  of  more  LEDs.   

If a cut edge has the possibility of making contact with a conductive surface or another cut edge, cover the cut 

edge with RTV sealant or conformal coating.

 

If one or more connection blocks exist on a cut/fold line, it is best 

to remove the connection block* to make a clean fold or cut. Using a pair of slip-joint pliers, grasp the connection 

block firmly (front side to back as illustrated at right) and rotate it either clockwise or counterclockwise while 

holding the Light Sheet in place. The connection block will unseat from the solder. Repeat for other connection 

blocks as needed and discard the removed block(s).

Short sheet-to-sheet connectors (B): When adjacent Auragami Light Sheets are mounted side-by-side with connection blocks aligned, the shorter 

sheet-to-sheet connection wires (B) should be used to interconnect multiple sheets. Their lengths are optimized so sheets align snugly. See Figure 1. 

When connecting Light Sheets that are already mounted to a fixed surface, the short connection wires (B) will need to be shaped as shown in Figure 

2 prior to pushing into connection blocks. Best practices include using two sheet-to-sheet connection wires for all adjacent Light Sheets in each Class 2 

circuit to minimize voltage drop. Dry-fit test for proper illumination prior to mounting Light Sheets to the mounting surface and again before the forward 

facing material is installed.

USING AURAGAMI

®

 ACCESSORIES

Figure 1

Figure 2

Figure 3

OR

*NEVER CUT OR ALTER LIGHT

SHEET(S) WHILE POWERED.

Long sheet-to-sheet connectors (C):

Use the long sheet-to-sheet connection wires (C) to bridge gaps and/or connect offset sheets as 

shown in Figure 3. 

Domed protective bumpers (D): 

Rated for 400 lbs each, the domed protective bumpers (D) included with each Light Sheet have 

been engineered to bear the weight of translucent materials in horizontal applications and act 

as a safeguard in vertical applications so that the forward facing material does not harm the 

Light Sheet’s integrated connection blocks or LEDs. Evo-Lite recommends using eight bumpers 

per Light Sheet (approximately six per square foot), spacing them evenly to distribute the weight 

of the forward facing material (see Figure 4) and to add a level of protection in vertical applications 

when the forward facing material will be positioned near the Light Sheet (see Figure 5). A rigid, 

non deforming mounting surface/substrate must be used with any weight bearing applications to 

avoid damaging the Auragami Light Sheet.

Cable management clips (G) (included in the power input kit sold separately): 

Route the connection wires so that the light from the LEDs is not blocked and hold the wires in this 

position using cable management clips with silicone adhesive backing (G) as shown in Figure 3. 

Once applied, let this adhesive backing cure for 10-30 minutes before routing wires through the 

clip. When possible, use a mechanical fastener to secure the clip. 

B

B

C

Integrated 5-pin 

connection block

Translucent (Forward Facing) Material

D

B

C

D

G

SHORT SHEET-TO-SHEET CONNECTION WIRES

LONG SHEET-TO-SHEET CONNECTION WIRES

PROTECTIVE BUMPERS

G

G

Translucent

(Forward Facing) 

Material

Integrated 5-pin 

connection block

D

Figure 5

Figure 4

CABLE MANAGEMENT CLIPS

8.85 mm

(0.35”)

10 mm

(0.39”)

9 mm

(0.35”)

12.8 mm (0.50”)

83 mm (3.26”)

149 mm (5.86”)

31 mm 

(1.22”)

Summary of Contents for Auragami AG1-24-RGBW Series

Page 1: ... more than 88 watts total The Light Sheet s FPC Flexible Printed Circuit design and integrated connection blocks have a 96 W 4 A at 24V DC capacity Do not exceed the capacity of the FPC and connections blocks in any configuration This product is rated IP65 and can be used in wet locations but not where water may accumulate When using any type of mechanical fastener make sure the fastener head does...

Page 2: ...shaped as shown in Figure 2 prior to pushing into connection blocks Best practices include using two sheet to sheet connection wires for all adjacent Light Sheets in each Class 2 circuit to minimize voltage drop Dry fit test for proper illumination prior to mounting Light Sheets to the mounting surface and again before the forward facing material is installed USING AURAGAMI ACCESSORIES Figure 1 Fi...

Page 3: ...eed 6 5 ft 2 meters from the Light Sheet s power supply input to the farthest end of any interconnected sheet If this distance exceeds 6 5 ft 2 meters splice an additional high count multi strand lead wire that is the appropriate gauge for the load and distance to the power input wire and connect this lead to a sheet that is centrally located within the interconnected sheets Alternatively split th...

Page 4: ...unique challenges we hope by making you aware of the following handling and installation guidelines you are empowered with knowledge for a successful installation As always your Evo Lite Systems Integration Specialist or any of our staff are ready to assist you with any questions that arise during your installation FOLDING MINIMUM RADIUS There is no minimum bending radius for Auragami Light Sheets...

Reviews: