background image

WWW.EVO-LITE.COM

   •   

[email protected]

   •   

1-888-887-2980

   •   ©2020 EVO-LITE, LLC  •  6240 W 54TH AVE., ARVADA, CO 80002  •  V2–3220

TEST BEFORE 

INSTALLING

Our production, packaging and shipping process is accompanied by a rigorous quality control procedure. 

All Auragami Light Sheets are subjected to a burn in period and are tested before packaging to ensure 

operation of the highest quality. Due to possible unforeseen issues with shipping and handling, we 

advise that all Light Sheets be inspected at time of delivery and dry-fit tested for proper illumination 

prior to mounting and again before the forward facing material is installed. 

FRAGILE 5-PIN 

CONNECTION 

BLOCKS

DISCONNECT POWER AT THE SOURCE BEFORE REMOVING ANY CONNECTION BLOCKS. 

The Light 

Sheet’s integrated 5-pin connection blocks are made of plastic which can be damaged if made to bear weight. 

Use domed protective bumpers (included) to bear the weight of any forward facing material in horizontal 

applications and to act as a safeguard to protect the Light Sheet in vertical applications.

DRILLING

DISCONNECT POWER AT THE SOURCE BEFORE ALTERING THE SHEET IN ANY WAY. 

Light Sheets have 

specific areas where holes can be made in the sheet. The smaller diameter circles on the Light Sheet 

(0.12” / 3 mm) indicate the maximum diameter of screw or other fastener’s shaft that can be used 

without causing damage to the Light Sheet’s power distribution grid. The larger diameter circle (0.24” / 6 

mm) is the maximum diameter of the screw head that can be used without causing damage. 

PRODUCT HANDLING, INSTALLATION & INTEGRATION ADVISORY

INSTALLATION 

TEMPERATURE 

Due to the characteristics of the 3M adhesive backing, installation environments and locations should 

be taken into consideration. Low temperatures can cause longer cure times for permanent adhesion. 

STORAGE

Store Auragami Light Sheets in a clean, dry area on a flat, horizontal surface. Do not open the anti-static 

envelope until ready to install. Ideal storage conditions: Temperature of 68° – 77° F, 50% humidity.

STORAGE

DO NOT CONNECT 

TO AC POWER

ANY DIRECT CONNECTION OF AURAGAMI LIGHT SHEETS TO AC CURRENT WILL DAMAGE THE LEDs. 

Be sure to use a UL Listed or UL Recognized Class 2, LPS or LVLE low voltage power supply that conforms 

to the voltage requirements of the Light Sheet. This information can be found on the Auragami Light 

Sheet and its packaging, as well as the power supply labeling.

Evo-Lite’s experience in providing backlighting solutions yields a unique perspective on the characteristics and underlying intuitive knowledge necessary to complete a 

successful installation of Auragami. Evo-Lite is committed to educating and supporting all our customers so every installation proceeds as smoothly as possible. Most 

installations offer their own unique challenges; we hope by making you aware of the following handling and installation guidelines you are empowered with knowledge 

for a successful installation. As always, your Evo-Lite Systems Integration Specialist or any of our staff are ready to assist you with any questions that arise during your 

installation.

FOLDING & 

MINIMUM RADIUS

There is no minimum bending radius for Auragami Light Sheets, however a single sheet may not be 

folded on itself because this could disrupt the flow of electricity through the folded sheet. Two separate 

IP65 sheets may be attached back-to-back since the 3M adhesive backing will act as non-conductive 

barrier. Light Sheets are not recommended for applications where a radius of less than 2” exists.

CUTTING

DISCONNECT POWER AT THE SOURCE BEFORE ALTERING THE SHEET IN ANY WAY.

  NEVER CUT 

AURAGAMI LIGHT SHEET WHILE POWERED. Field cutting of the Light Sheet does not void UL Listing. LEDs 

can lose input power if cut lines are not followed. Avoid cut edge contact with any conductive material(s), 

including other cut edges of Light Sheets. See also Wet Location Use below.

SOLDERING

DISCONNECT POWER AT THE SOURCE BEFORE ALTERING THE SHEET IN ANY WAY. 

Solder sheets or 

strips of Auragami together or solder power input(s) to Light Sheets. The Light Sheet’s copper pads are 

engineered to handle 4 A of load and polarity is noted by the + and - next to each copper pad. Use 20 

AWG stranded copper wire for up to 4 A of load and follow electronics soldering best practices. 

FASTENING

USE PAN HEAD, DOMED, OR ROUND HEAD FASTENERS, NOT TAPERED SCREWS. 

Never screw the 

fastener so much that it deforms the Light Sheet. Only penetrate the Light Sheet within the smallest 

of the two concentric circles marked on the sheet (see Drilling above for screw size limitations). For 

suspended applications, use mechanical fasteners with an appropriate spacing to avoid sagging.  

WET LOCATION 

USE

Auragami Light Sheets are rated IP65. This rating is total protection against dust ingress as well as water 

projected by a nozzle against the enclosure from any direction for a limited time and may be used in wet 

locations, but not where standing water can accumulate. Cut edges of IP65 can optionally be sealed from 

moisture with an RTV Silicone Sealant or conformal coating.

IP65

POWER, CONTROL 

& WIRING

For optimal power distribution and to minimize voltage drop, it is recommended that multi-strand, high 

strand count wiring be used for all low voltage DC connections. Wire gauge should be appropriate based 

upon system voltage and wire lengths to further minimize voltage drop.  Power supplies, drivers and 

controls should be installed in well ventilated enclosures and/or per manufacturers recommendations. 

It is the customer’s responsibility to ensure all components and installation practices meet or exceed 

local codes and requirements.

Auragami® is a patented product of Evo-Lite, LLC. For more information please visit 

www.evo-lite.com/patent

Summary of Contents for Auragami AG1-24-RGBW Series

Page 1: ... more than 88 watts total The Light Sheet s FPC Flexible Printed Circuit design and integrated connection blocks have a 96 W 4 A at 24V DC capacity Do not exceed the capacity of the FPC and connections blocks in any configuration This product is rated IP65 and can be used in wet locations but not where water may accumulate When using any type of mechanical fastener make sure the fastener head does...

Page 2: ...shaped as shown in Figure 2 prior to pushing into connection blocks Best practices include using two sheet to sheet connection wires for all adjacent Light Sheets in each Class 2 circuit to minimize voltage drop Dry fit test for proper illumination prior to mounting Light Sheets to the mounting surface and again before the forward facing material is installed USING AURAGAMI ACCESSORIES Figure 1 Fi...

Page 3: ...eed 6 5 ft 2 meters from the Light Sheet s power supply input to the farthest end of any interconnected sheet If this distance exceeds 6 5 ft 2 meters splice an additional high count multi strand lead wire that is the appropriate gauge for the load and distance to the power input wire and connect this lead to a sheet that is centrally located within the interconnected sheets Alternatively split th...

Page 4: ...unique challenges we hope by making you aware of the following handling and installation guidelines you are empowered with knowledge for a successful installation As always your Evo Lite Systems Integration Specialist or any of our staff are ready to assist you with any questions that arise during your installation FOLDING MINIMUM RADIUS There is no minimum bending radius for Auragami Light Sheets...

Reviews: