background image

 

5200 NW 108th Avenue

 

Sunrise, FL 33351 U.S.A.  

(800) 762-1084 – (954) 929-1115 

FAX (954) 929-5560 

www.chauvetlighting.com

 

SkyScan™ 4000 

 

 

 

 
 
 
 
 
 

 
 
 
 

USER MANUAL 

 

Snapshot 

OK on Dimmer 

 

For Use in Dry 

Outdoor Location 

 

For Use in Wet 

Outdoor Location 

 

Sound Activated 

 

DMX512 

 

Master/Slave 

 

115V/230V Switch 

 

Replaceable Fuse 

 

Duty Cycle 

 

Summary of Contents for SkyScan 4000

Page 1: ...2 1084 954 929 1115 FAX 954 929 5560 www chauvetlighting com SkyScan 4000 USER MANUAL Snapshot OK on Dimmer For Use in Dry Outdoor Location For Use in Wet Outdoor Location Sound Activated DMX512 Master Slave 115V 230V Switch Replaceable Fuse Duty Cycle ...

Page 2: ...ns 4 2 Introduction 5 Features 5 Product Overview 5 3 Setup 6 Lamp 6 Lamp Installation 6 Fuse Replacement 8 Mounting 8 Orientation 8 Rigging 8 4 Operating Instructions 9 Operation 9 To turn the power to the lamp on 9 To activate the Pan rotation 9 Contact Us 12 5 Appendix 13 General Maintenance 13 Returns Procedure 13 Claims 13 Technical Specifications 14 ...

Page 3: ...fixture s listed current rating is its average current draw under normal conditions All fixtures must be powered directly off a switched circuit and cannot be run off a rheostat variable resistor or dimmer circuit even if the rheostat or dimmer channel is used solely for a 0 to 100 switch Before applying power to a fixture check that the source voltage matches the fixture s requirement Check the f...

Page 4: ... fixture to fastening device using a safety chain Never carry the fixture solely by its head Use its carrying handles Maximum ambient temperature Ta is 104 F 40 C Do not operate fixture at temperatures higher than this In the event of a serious operating problem stop using the unit immediately Never try to repair the unit by yourself Repairs carried out by unskilled people can lead to damage or ma...

Page 5: ...ized pan 120 manual tilt 40 Quad power switches control lamp s intensity 1k 2k 3k or 4k Silent hot restrike ignition Variable mechanical zoom Ingress Protection IP33 Product Overview Access panel Tilt Adjustment knob Fan intake vents Front lens Transport locking wheels Carrying handle Power input connector ...

Page 6: ...he fan as this is attached to the back cover and is easy to damage when removing the panel 3 Then remove the front cover with a Phillips 2 screwdriver Although the lamp is installed through the back of the fixture you will need to gain access to the front of the fixture to detach the front end of the lamp This is done with a crescent wrench 4 Remove the lamp by loosening and detaching both ends of...

Page 7: ... from their bases inside their safety covers Leaving them to roll around unprotected on a desk or shelf can result in micro cracks in the surface of the quartz glass and burst lamps later on If the lamp is inadvertently operated inside its safety cover the sleeve will melt within a few seconds and the lamp will be unusable When removing lamps the reverse procedure must be followed first put the sa...

Page 8: ...N This fixture may only be mounted in a standing vertical position provided there is adequate room for ventilation and movement Note this fixture MUST be positioned in an upright position to allow proper cooling ventilation and IP rating RIGGING It is important never to obstruct the fan or vents pathway Adjust the angle of the fixture by loosening both knobs and tilting the fixture After finding t...

Page 9: ...the desired light output 2 Please wait 30 seconds between activating each additional lamp switch TO ACTIVATE THE PAN ROTATION 1 Locate the pan motor switch 2 Switch it to the ON position to enable bi directional rotation 3 To disable bi directional rotation switch this to the OFF position Note the pan cannot be manually adjusted Pan motor switch Fuse X4 15A 250V Lamp power switch X4 Power Indicato...

Page 10: ...THE ZOOM OF THE FIXTURE 1 Locate the ZOOM adjustment of the fixture highlighted in the diagram below 2 Turn the adjustment knob clockwise to increase the beam angle 3 Turn the adjustment knob counter clockwise to decrease the beam angle Zoom adjustment knob ...

Page 11: ...ing Lamp may be at end of its life ü Light will not come on after power failure Some discharge lamps require a cooling off period before the electronics in the fixture can kick start it again wait 5 to 10 minutes before powering up ü Loss of signal Use only DMX cables Install terminator Note Keep DMX cables separated from power cables or black lights ü ü ü ü Moves slow Check 220 110v switch for pr...

Page 12: ...formation CHAUVET 5200 NW 108th Avenue Sunrise FL 33351 voice 954 929 1115 fax 954 929 5560 toll free 800 762 1084 Technical Support CHAUVET 5200 NW 108th Avenue Sunrise FL 33351 voice 954 929 1115 Press 4 fax 954 929 5560 Attention Service World Wide Web www chauvetlighting com ...

Page 13: ...aning fluid Always dry the parts carefully Clean the external optics at least every 20 days Clean the internal optics at least every 30 60 days Returns Procedure Returned merchandise must be sent prepaid and in the original packing call tags will not be issued Package must be clearly labeled with a Return Merchandise Authorization Number RMA Products returned without a RMA will be refused Call CHA...

Page 14: ...tion current 2K 1481W 13 7A max 0 63 PF at 230V Power Consumption current 3K 2 300W 21 6A max 0 68 PF at 230V Power Consumption current 4K 3 200W 26 4A max 0 73 PF at 230V Inrush Power 1 2A 26 4A at 230V LIGHT SOURCE Lamp XQ4000 4000W 6000 K 500hrs PHOTO OPTIC Luminance 27m 490 000 lux Beam Angle 1 15 RANGE Pan motorized 120 Tilt manual 40 THERMAL Maximum ambient temperature 104 F 40 C ORDERING IN...

Reviews: