214
Q210 SELF-CONTAINED WATER-COOLED
NOTE: These characteristics may vary depending on
operating conditions.
Cycle Times
Freeze Time + Harvest Time = Cycle Time
Times in minutes
24 Hour Ice Production
Based on average ice slab weight of 2.44 - 2.75 lb (1107 – 1247 g).
Regular cube derate is 7%
Water regulating valve set to maintain 230 PSIG discharge pressure
Operating Pressures
Suction pressure drops gradually throughout the freeze cycle.
Air Temp.
Around Ice
Machine °F/°C
Freeze Time
Harvest
Time
Water Temperature °F/°C
50/10
70/21
90/32
70/21
14.5-16.5
15.6-17.8
19.2-21.8
1.0-2.5
80/27
14.8-16.9
16.1-18.3
19.8-22.5
90/32
15.6-17.8
17.0-19.3
21.2-24.0
100/38
16.1-18.3
17.5-19.9
21.9-24.9
Air Temp. Around
Ice
Machine °F/°C
Water Temperature °F/°C
50/10
70/21
90/32
70/21
220
205
170
80/27
215
200
165
90/32
205
190
155
100/38
200
185
150
Condenser Water
Consumption
90/32 Air Temperature Around Ice Machine
Water Temperature °F/°C
50/10
70/21
90/32
Gal/24 hours
160
270
1500
Air Temp.
Around Ice
Machine
°F/°C
Freeze Cycle
Harvest Cycle
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
50/10
225-235
60-35
160-180
70-95
70/21
225-235
60-36
160-180
70-95
80/27
225-235
60-36
165-185
80-100
90/32
225-240
60-37
170-190
90-115
100/38
225-240
60-38
175-195
100-120
110/43
225-245
60-38
180-200
100-120
Summary of Contents for Q130 series
Page 2: ......
Page 16: ...16 Part Number 8001119 10 19 SM50 MODEL SERIAL NUMBER PLATE ...
Page 36: ...36 Part Number 8001119 10 19 This Page Intentionally Left Blank ...
Page 98: ...98 Part Number 8001119 10 19 This Page Intentionally Left Blank ...
Page 202: ...202 Part Number 8001119 10 19 This Page Intentionally Left Blank ...
Page 234: ...234 Part Number 8001119 10 19 This Page Intentionally Left Blank ...
Page 235: ......