23
Installation
Location of Ice Machine
The location selected for the ice machine must meet
the following criteria. If any of these criteria are not
met, select another location.
•
The location must be indoors.
•
The location must be free of airborne and other
contaminants.
•
Air temperature:
•
Q130/Q170/Q210/Q270/QM45 must be at
least 40°F (4°C) but must not exceed 110°F
(43.4°C).
•
QM20/QM30 must be at least 50°F (10°C) but
must not exceed 113°F (45°C).
•
SM50 must be at least 50°F (10°C) but must
not exceed 110°F (43°C).
•
The location must not be near heat-generating
equipment or in direct sunlight.
•
The location must be capable of supporting the
weight of the ice machine and a full bin of ice.
•
The location must allow enough clearance for
water, drain, and electrical connections in the
rear
of the ice machine.
•
The location must not obstruct airflow through or
around the ice machine (condenser airflow is in
and out the front). Refer to the chart below for
clearance requirements.
•
The ice machine must be protected if it will be
subjected to temperatures below 32°F (0°C).
Failure caused by exposure to freezing
temperatures is not covered by the warranty.