Suction Pressure High Checklist
Improper Installation
•
Refer to “Installation and Visual Inspection
Discharge Pressure
•
Discharge pressure is too high, and is affecting
suction pressure, refer to “Discharge Pressure
Improper Refrigerant Charge
•
Overcharged
•
Wrong type of refrigerant
•
Non-condensables in system
Other
•
Non-Manitowoc components in system
•
Hot gas valve leaking
•
TXV flooding (check bulb mounting)
•
Defective compressor