132
Q130/Q170/Q210/Q270 Ice Machines Only
(continued)
4
Stops on
safety limit:
1
If discharge pressure
is High or
Low
, refer to freeze cycle hig
h or
low discharge pressure problem checklist to eliminate problems
and/or components not listed on this table before proceeding.
If
suction
pressure
is
High
or
Low
refer
to
freeze
cycle
high
or
low
suction pressure problem checklist to eliminate problems and/or
components not listed on this table before proceeding.
Suction
pressure is
High
3
Stops on
safety limit:
1 or 2
Suction
pressure is
High
2
Stops on
safety limit:
1
Suction
pressure is
Low
1
Stops on
safety limit:
1 or 2
Suction
pressure is
High
Operational
Analysis
Safety limits
Refer to “Analyzing Safety
Limits” to eliminate all non-
refrigeration problems.
Freeze cycle
Discharge Pressure
_______
_______
_______
1 minute
Middle End
Freeze cycle
Suction Pressure
_______
_______
_______
1 minute
Middle End