216
Q270 SELF-CONTAINED WATER-COOLED
NOTE: These characteristics may vary depending on
operating conditions.
Cycle Times
Freeze Time + Harvest Time = Total Cycle Time
Times in minutes
24 Hour Ice Production
Based on average ice slab weight of 2.44 - 2.75 lb (1107 – 1247 g).
Regular cube derate is 7%
Water regulating valve set to maintain 240 PSIG discharge pressure
Operating Pressures
Suction pressure drops gradually throughout the freeze cycle
Air Temp.
Around Ice
Machine
°F/°C
Freeze Time
Harvest
Time
Water Temperature °F/°C
50/10
70/21
90/32
70/21
10.6-12.2
12.3-14.0
13.5-15.4
1.0-2.5
80/27
10.8-12.4
12.6-14.3
13.8-15.7
90/32
11.0-12.6
12.8-14.7
14.1-16.1
100/38
11.3-12.9
13.1-15.0
14.5-16.5
Air Temp. Around
Ice
Machine °F/°C
Water Temperature °F/°C
50/10
70/21
90/32
70/21
290
255
235
80/27
285
250
230
90/32
280
245
225
100/.8
275
240
220
Condenser
Water
Consumption
90/32 Air Temperature Around Ice Machine
Water Temperature °F/°C
50/10
70/21
90/32
Gal/24 hours
240
410
2740
Air Temp.
Around Ice
Machine
°F/°C
Freeze Cycle
Harvest Cycle
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
Discharge
Pressure
PSIG
Suction
Pressure
PSIG
50/10
235-245
52-24
175-210
80-95
70/21
235-245
54-24
175-210
80-95
80/27
235-250
56-24
175-210
80-95
90/32
235-255
58-24
175-210
80-95
100/38
235-260
60-24
175-210
80-95
Summary of Contents for Q130 series
Page 2: ......
Page 16: ...16 Part Number 8001119 10 19 SM50 MODEL SERIAL NUMBER PLATE ...
Page 36: ...36 Part Number 8001119 10 19 This Page Intentionally Left Blank ...
Page 98: ...98 Part Number 8001119 10 19 This Page Intentionally Left Blank ...
Page 202: ...202 Part Number 8001119 10 19 This Page Intentionally Left Blank ...
Page 234: ...234 Part Number 8001119 10 19 This Page Intentionally Left Blank ...
Page 235: ......