Adjusting
If the ice machine stops before the bin is full or runs
after the bin is full, ambient temperatures are probably
high or low and the bin thermostat can be adjusted as
follows:
HAZARDOUS MOVING PARTS
Power is supplied to ice machine during this
procedure. Avoid contact with the fan blade and
the electrical connections.
1. To access the thermostat, remove the two screws
attaching the front grill and remove the grill.
2. Remove the lower white plastic panel by pulling
straight down.
3. Turn the thermostat to the left to decrease the
level of ice before automatic shut-off. Turn to the
right to increase the level of ice before automatic
shut-off.
4. Reassemble the plastic panel and grill.
!
Warning