165
1. Remove the back panel to access the bin
thermostat.
2. Disconnect both wires #12 and #1 from the bin
thermostat and check the resistance across the
bin thermostat terminals.
NOTE: After covering/uncovering the bulb holder with
ice, wait at least three minutes to allow the thermostat
to react. (Open/Close)
No Ice on Bulb
Ice on Bulb
Result
Closed (O)
Open (OL)
Thermostat good
Open (OL)
Closed (O)
Replace
thermostat
DECREASE
LEVEL OF
ICE IN BIN
INCREASE
LEVEL OF
ICE IN BIN
1.5"
(3.8 CM)
4"
(10.2 CM)
SV1680B
WARMER
COOLER