153
Suction Pressure High Checklist
Improper Installation
•
Refer to “Installation and Visual Inspection
Discharge Pressure
•
Discharge pressure is too high, and is affecting
suction pressure, refer to “Discharge Pressure
Improper Refrigerant Charge
•
Overcharged
•
Wrong type of refrigerant
•
Non-condensables in system
Other
•
Non-Manitowoc components in system
•
Hot gas valve leaking
•
Defective compressor
•
Water inlet valve leaking
Suction Pressure Low Checklist
Improper Installation
•
Refer to “Installation and Visual Inspection
Discharge Pressure
•
Discharge pressure is too low, and is affecting
suction pressure, refer to “Freeze Cycle Discharge
Pressure Low Checklist” on page
Improper Refrigerant Charge
•
Undercharged
•
Wrong type of refrigerant
Summary of Contents for Q130 series
Page 2: ......
Page 16: ...16 Part Number 8001119 10 19 SM50 MODEL SERIAL NUMBER PLATE ...
Page 36: ...36 Part Number 8001119 10 19 This Page Intentionally Left Blank ...
Page 98: ...98 Part Number 8001119 10 19 This Page Intentionally Left Blank ...
Page 202: ...202 Part Number 8001119 10 19 This Page Intentionally Left Blank ...
Page 234: ...234 Part Number 8001119 10 19 This Page Intentionally Left Blank ...
Page 235: ......