Ref.: WB-VL-65 DSP LX Premium - OM Ver.1.6 (B2927)
4
2.5.
SAFETY FEATURES
2.5.1.
WHEEL GUARD AND ITS SAFETY INTERLOCK SWITCH
The Wheel guard prevents flying out of the weights added on the Wheel rim or
stone / foreign particles sticking to the tyre in any direction except towards the
floor. A safety Interlock switch is provided to ensure that the Wheel guard is
closed during spinning of wheel. If the Wheel guard is not closed during
spinning, an error message “
Wheel Guard Not closed
” will be displayed. By
closing the guard, error message will disappear and the wheel starts spinning.
This feature is to ensure the safety to the operator.
2.5.2.
HOME POSITION INDICATOR FOR DISTANCE MEASURING ROD
To avoid the wheel from hitting the Distance measuring rod while running ie., if
the Distance measuring rod is not in home position, the wheel run will not be
carried out and an Error code “
Distance rod is not in Home position
” will be
displayed. Move the Distance measuring rod to home position to continue.
2.5.3.
DOUBLE CLICK OF KEYS FOR SPINNING OF WHEEL
During Balancing run, for spinning the wheel the
key must be pressed
twice within a second. This is to avoid accidental spinning of wheel.
2.5.4.
CONTROL FUSE
Control fuses are incorporated to protect the electronic assemblies against
short circuit & high current. AC (Inlet) socket with Fuse holders is mounted on
the rear side of Main cabinet which can be easily accessed from outside for
replacing the blown fuse. Always replace the Control fuse with same type and
rating of CE marked Fuse.
2.6.
SAFETY LABEL INFORMATION
Sticker, Operation,
Safety & Rating
(LCV)
(Part No. H3711)