Ref.: WB-VL-65 DSP LX Premium - OM Ver.1.6 (B2927)
22
7.4.
BALANCING
Daily, when the Balancer is switched ON for the first time, allow 15 minutes of
warm-up time for the stabilisation of the equipment
In case of power failure in the midst of Balancing program/functions, the
program should be executed again from the start
Select
key & then press
key to shut down the system. Once pressed,
wait till “No Signal” message is displayed and then turn off the
ON/OFF Switch
There are two types of balancing as explained below:
DYNAMIC BALANCING (Two plane balancing)
This refers to the balancing carried out on the Inner and Outer planes of wheel. In this
type, unbalance readings measured by the system on both planes will be displayed.
Dynamic balancing can be carried out for normal LCV including Alloy rims.
STATIC BALANCING (Single plane balancing)
Static balancing is generally done for wheels having smaller Rim width (<
3”) & Alloy
wheels. Balancing weights is applied on the Inner plane only.
Split weight functions cannot be done in Static balancing mode
Switch ON the equipment and wait for a minute (approx.). Program will load & following
WELCOME
screen will be displayed. DO NOT interrupt the system while booting:
Premium
Fig. 18
Use Navigation keys to select
button and then press
key to go to
WHEEL RUN screen
Press
key to choose the preferred languages available in the screen and
then press
key to save the settings
Press
key to know the functions of keys applicable in the respective
screens
Press
key to update the balancing program in field. This feature should be
used only by authorised Service personnel
Press
key to go to previous screen and also to stop the wheel spin
Press
key to clear any error message & proceed further
If “
Error in communication. Check cables and power
" message is displayed,
press
key to clear the message. If the error is repeated again, check the
serial communication cable connection by authorised service personnel
Use Navigation keys to select
/
/
/
/
buttons in the
WELCOME
screen
& press
key.