Ref.: WB-VL-65 DSP LX Premium - OM Ver.1.6 (B2927)
37
Move the Distance/Diameter measuring rod & touch the inner plane profile (Ref.Fig.21)
of the Rim properly and hold it for 3 seconds until Audio indication and then move the
Distance/Diameter measuring rod to its home position.
Fig. 42
Press
key to save the Diameter calibration values. “
Dia calibration saved and
completed
” message will be displayed briefly.
Mount a Wheel & ensure the Rim diameter measured in
RIM PARAMETERS
screen is
as per the Wheel Diameter specifications within tolerance limit of ±0.3”.
9.3.
WIDTH CALIBRATION
For recording the Zero position accurately, Width rod should be rested on the
Stopper position and also 90° in X axis at the same time
Use navigation keys to select
WIDTH CALIBRATION
& press
key. Following
screen will be displayed:
Fig. 43
Keep the Width measuring rod in zero position (ie. Stopper Position) and ensure the
displayed Width voltage & Outer Dia voltage is 1.00V±0.1V & 2.50V±0.1V respectively.
If the displayed Outer dia voltage is not within specification, move the Width
assembly to make it perpendicular with the cabinet and touch it with the
stoppers. Now loosen the Grub screws to rotate the outer dia shaft for
achieving the required voltage and tighten the screws in that position as
shown in Fig.43
If the displayed Width voltage is not within specification, move the Width
assembly to make it perpendicular with the cabinet and touch it with the
stoppers. Now loosen the Allen screws available at the rear side of Width
board housing and take out the Width measurement pipe. Now adjust the shaft
in the Width board for achieving the required voltage. Fix the Width
measurement pipe by ensuring perpendicularity as shown in Fig.43
1.
If Width rod is either not in its zero position properly or the Width/Outer Dia
voltage is not within specifications and
key is pressed, ”Width rod in Zero
position” message will be displayed