80
BA550001-en
14.2.2
Overview of components for seal kit
Telescopic stage
Description
Dimensions
Stage 1 for 2S/3S
Scraper
80x88x7
Rod seal
80x90x11
Guide tape
80x85x25
O-ring
Ø100x2
Stage 2 for 2S/3S
Scraper
115x127x10
Rod seal
115x125x13
Guide tape
115x120x25
O-ring
Ø150x3
Piston seal
140x125x10
Level 3 for 3S
Scraper
170x182x10
Rod seal
170x190x16
Guide tape
170x175x25
O-ring
Ø230x3
Piston seal
220x200x14
Drain the hydraulic oil (see sections "Replacing the hydraulic oil" to "Replacing
the hydraulic unit").
14.2.3
Work sequence for changing seal kit, 2S | 3S pit jacks
Work steps Section 1:
1 Fit the installation wrench and fit the mandrel for the piston rod.
2 Using a lifting device, pull the piston stand upwards on the eyebolt with a
slight pull (approx. 20 mm). Lifting the jack off the ground should be
avoided.
3 Then remove the upper screw plug.