BA550001-en
53
Malfunction
Possible cause
Remedy
Valve / coil defective
Replace valve / coil
(customer service)
Wrong valve
Check type designation
(EMP = prop. Valve)
Pit jack does not retract
or retracts with great
difficulty
Wrong valve
Check type designation
(EMP = prop. Valve)
Hydraulic valve / block
defective (rare)
See above
Mech. Damage to the pit
jack
Check the piston rod and
guide bush for visible
damage
Loosen the bleed screw
and observe whether the
piston rod lowers. Try to
turn the piston rod. If the
piston rod can be
lowered and rotated,
there is no mech.
Damage before
Customer service
Seal defective, oil
leakage at the guide
bushing
Customer service
Piston rod does not fully
extend
Too little oil
Refill oil (HLP-D-22)
Air in the system
See above