IMPULSE®•G+/VG+ Series 4 Profinet Installation Manual - August 2014
28
Magnetek-Specific Control and Status Words
The Control Word and the Status Word
The contents of the Control Word and the Status Word are detailed in Table 10: Magnetek-Specific
Control Word and Status Word.
Frequency Reference
Frequency Reference is a 16-bit word containing the desired output frequency.
Output Frequency
Output Frequency is a 16-bit word containing the current output frequency of the drive.
Table 10: Magnetek-Specific Control Word and Status Word
Magnetek-Specific Control Word
Magnetek-Specific Status Word
Bit
Description
Bit
Description
0
Run Bit
0
Running
1
Reverse run bit
1
Zero Speed
2
EF0
2
Reverse Operation
3
Fault Reset
3
Reset Signal Input Active
4
ComFref
4
At Speed
5
ComCtrl
5
Ready
6
DI3
6
Alarm
7
DI4
7
Fault
8
DI5
8
oPE Fault
9
DI6
9
Uv Return
10
DI7
10
2nd Motor
11
DI8
11
ZSV