IMPULSE®•G+/VG+ Series 4 Profinet Installation Manual - August 2014
33
Cyclic Messaging
SI-EP3 supports cycle times of 8 to 512 ms.
CW: Control Word
SW: Status Word
REF: Reference
ACT: Actual Value
PZD: Configurable inputs and outputs
Magnetek Acyclic Parameter Access Mechanism
All drive parameters can be read and written under address 0x8000 by performing a read or write
with the index value of the corresponding parameter address in the drive. Refer to the Series 4
Instruction Manual for a list of these parameter addresses.
28
Analog Input 3 MSB
29
Analog Input 3 LSB
30
Configurable Input 1 MSB
31
Configurable Input 1 LSB
32
Configurable Input 2 MSB
33
Configurable Input 2 LSB
34
Configurable Input 3 MSB
35
Configurable Input 3 LSB
36
Configurable Input 4 MSB
37
Configurable Input 4 LSB
38
Configurable Input 5 MSB
39
Configurable Input 5 LSB
Bytes
Description