214323
190
Revision B
1003615
A
B
Figure 4.125: Combine Header Control System
3.
Push AUTO HEADER HEIGHT button (A). LED light (B) should
flash continuously indicating that it is in standby mode and
waiting for a response from the Operator.
1003616
A
Figure 4.126: Header Down Button
4.
Briefly press HEADER DOWN button (A). The header should
lower automatically and the LED light should stay
illuminated indicating that the auto height system is
engaged and working.
1003613
A
B
Figure 4.127: Combine Header Control System
5.
Turn HEIGHT dial (A) to increase or decrease the ground
pressure.
6.
Turn SENSITIVITY dial (B) to control how quickly the AHHC
reacts to varying ground conditions.