214323
158
Revision B
1026252
B
A
Figure 4.58: Case IH Combine Display
7.
Select YES (A) from the REEL FORE-BACK list (if applicable).
8.
Set HEIGHT SENSITIVITY (B) to the desired value. The
recommended starting value is 180.
1026254
A
B
Figure 4.59: Case IH Combine Display
9.
Select YES for FORE-AFT CONTROL (A) and HDR FORE-AFT
TILT (B) (if applicable).
A
B
C
D
ϭϬϯϵϵϲϯ
Figure 4.60: Case IH Combine Display
10. Select the HEAD2 tab at the bottom of the page.
11. Ensure that DRAPER (A) is selected from the HEADER
TYPE list.
NOTE:
If the recognition resistor is plugged into the header
harness, you will not be able to change the header type.
12. Set the cutting type to PLATFORM (B).
13. Set the appropriate HEADER WIDTH (C) and HEADER
USAGE (D) values.