![MacDon FD75 Operator'S Manual Download Page 230](http://html.mh-extra.com/html/macdon/fd75/fd75_operators-manual_685691230.webp)
214323
212
Revision B
1018425
A
Figure 4.163: Header Down Switch
3.
On the ground speed lever (GSL), press HEADER DOWN
button (A). The sensor values on the HEADER CALIBRATION
page will change as the header falls.
NOTE:
The header needs to be fully lowered and then fully raised.
The sensor voltage range should be between 0.7 and 4.3 V.
If the values do not fall within that range, the height
sensors will need to be adjusted. For instructions, refer to
4.4.2 Adjusting Voltage Limits, page 137
1018422
A
Figure 4.164: Header Calibration
4.
Touch CALIBRATE icon (A).
1018438
Figure 4.165: Header Calibration Warning
5.
The hazard message for the HEADER CALIBRATION
procedure will appear. Do
NOT
touch the green check mark
until all of the conditions listed on the page have been met.
6.
Touch the green check mark to start the CALIBRATION
WIZARD.
Summary of Contents for FD75
Page 8: ......
Page 43: ...214323 25 Revision B Figure 2 1 Header Width 1018123 A B PRODUCT OVERVIEW ...
Page 71: ...214323 53 Revision B For more information refer to Table 3 4 page 51 OPERATION ...
Page 306: ......
Page 360: ......
Page 524: ......
Page 538: ......