13. When all the calibration steps have been completed, the message CALIBRATION SUCCESSFUL is displayed on the page.
Exit the CALIBRATION menu by pressing the ENTER or ESC key.
NOTE:
If the float was changed to a heavier setting to complete the ground calibration procedure, readjust the float after the
calibration procedure is completed.
14. If the AHHC system still does not function properly, perform the combine
’
s maximum stubble height calibration
procedure.
4.7.6
Setting Preset Cutting Height
–
Case 7010/8010, 7120/8120/9120,
7230/8230/9230, 7240/8240/9240
Your Case IH 7, 8, or 9 series combine can have up to two auto header height control header height presets configured at
one time.
NOTE:
Changes may have been made to the combine controls or the display since this document was published. Refer to the
combine operator
’
s manual for updates.
DANGER
Check to be sure all bystanders have cleared the area.
1023375
A
B
C
D
E
Figure 4.66: Case Combine Controls
A - Set #1 Switch
B - Set #2 Switch
C - Header Height Mode Light
D - Header Height Mode Light
E - Fine Adjust Switch
1.
Engage the separator and the header.
2.
Manually raise or lower the header to the desired cutting
height.
3.
Press SET #1 switch (A). HEADER HEIGHT MODE light (C)
(next to SET #1 switch) turns on.
4.
Manually raise or lower the header to a second desired
cutting height.
5.
Press SET #2 switch (B). HEADER HEIGHT MODE light (D)
(next to SET #2 switch) turns on.
Summary of Contents for FD75