© 2018 MA Lighting Technology GmbH - Dachdeckerstr. 16 - 97297 Waldbüttelbrunn - Germany
Phone +49 5251 688865-30 - [email protected] - www.malighting.com
1
Iris
(Iris)
Iris = 10 %
Iris = 80 %
Open or close the Iris
Control
Control
(CTRL)
The Control channel of the Master Layer is used to
switch to the Fullscreen View or to shut down the VPU
via the desk.
These functions are available as buttons in the Smart
View:
- No Operation: --- - Shutdown: Shutdown VPU -
Restart: Restart VPU
- Fullscreen: Fullscreen Mode - Windowed: Windowed
Mode
- Enter PM: Start Pixel Mapper - Leave PM: Leave Pixel
Mapper
- Enter SMode: Enters the Show Mode - Leave SMode:
Leaves the Show Mode
Shapers
Shaper
(1A; 1B; 2A; 2B; 3A; 3B; 4A; 4B)
1A=
0
; 1B=0; 2A=
0
;
2B=0; 3A=
0
; 3B=0;
4A=
0
; 4B=0 %
1A=
30
; 1B=0; 2A=
30
;
2B=0; 3A=
30
; 3B=0;
4A=
30
; 4B=0 %
With the beam shapers the resulting image can be
masked variable with four shapers each with 2
channels A and B.
With the Blade switch shapers can be switched on or
off.
Video
VObj
(Image)
Image = no Image
Image = Circle
Select the image for the iris mask
*As described in
Eff1 Type…Eff4 Type
148 of 218
grandMA2 User Manual - Features Attributes and Functions
Version 3.4 – 2018-07-25