Equipment and Cable Installation for Metropolis
®
DMXplore Shelf (Wall-Mount)
Planning
1 - 4
365-372-334 R2.0
Issue 4, November 2004
1
Heat Baffle
(848862181)
If the
Metropolis
®
DMXplore
Wall-Mount
shelf is
to be installed above or below existing
equipment in a rack that does not have a heat
baffle, then a heat baffle must be installed
between the shelf and the existing equipment. If
there is space left in the bay-frame above the
last
Metropolis
®
DMXplore
shelf installed, a heat
baffle must be installed above the shelf to
prevent accidental damage to the power cables
at the top of the shelf.
Screwdriver(s)
A screwdriver(s) with the appropriate head(s) is
(are) required for securing the mounting screws,
repositioning the mounting brackets, and installing
the interfacing cables.
1
RJ-45 Crimping tool
The crimping tool is required for terminating DS1
blunt-cut cables to a RJ-45 connector.
1
Wire-Wrap Gun
R-4496A
The wire-wrap gun is required for terminating DS1
cable and must be able to accommodate 24-gauge
wire.
1
ESD Wrist Strap
R-4987C
A wrist strap must be worn when handling circuit
packs. Use the electrostatic discharge (ESD) jack
provided on the shelf.
1
Torque Wrench
(R-5952)
A torque wrench (50-250 IN-LBS) is used when
tightening the Metropolis
®
DMXplore shelf to the
frame. It is also used when reattaching the mounting
brackets to the Metropolis
®
DMXplore
shelf.
1
Torque Screwdriver
A torque screwdriver is used to attach the 48 Volt
wiring to the terminal block.
1
Metric & Inch Series Tool
Set
R - 6001
Because some Optical Networking Products (also
know as Transport) may have some metric fasteners,
please ensure that the proper metric tools are
available.
1
Multimeter (Optional)
ITE-6379C
The voltmeter must be capable of measuring DC
voltage in the 40 to 60 volt range. The use of the
voltmeter is optional since the shelf will alarm or
shut down if the proper voltage is not supplied.
1
Ohmmeter
ITE-6379C
An ohmmeter is required to verify that the
Metropolis
®
DMXplore is properly grounded.
Quantity
Description
Comments
Summary of Contents for Metropolis DMXplore
Page 8: ... C O N T E N T S v i i i 365 372 334 R2 0 Issue 4 November 2004 ...
Page 16: ... T A B L E S x v i 365 372 334 R2 0 Issue 4 Novmeber 2004 Glossary ...
Page 286: ... Backplane Pin Replacement Replacement Methods D 1 0 365 372 334 R2 0 Issue 4 November 2004 ...
Page 292: ... Installation Checklist Overview E 6 365 372 334 R2 0 Issue 4 November 2004 ...
Page 326: ... G L O S S A R Y G L 3 0 365 372 334 R2 0 Issue 4 November 2004 ...