Single-Mode Fiber Testing
Requirements
All fibers shall be tested after they are installed as follows:
•
All fibers shall be tested after installation, but prior to turn-up
•
Before fibers are tested, they shall be labeled properly and all
cable tags shall be removed.
•
A 1310nm or 1550nm test source and an ITE# 7116 (or
equivalent) optical power meter shall be used to perform all tests.
•
The light source shall first be measured for a reference
point/baseline.
•
No fiber jumper may have a measured loss of more than 2 dB.