Powering and Initial Circuit Pack Installation for
Metropolis
®
DMXplore Shelf (Rack-Mount)
Initial Circuit Pack Installation
...........................................................................................................................................................................................................................................................
4 - 1 3
365-372-334 R2.0
Issue 4, November 2004
...........................................................................................................................................................................
Step 5
Remove the second Main OLIU from the packing material.
Important!
When installing two Main OLIUs, both circuit packs
must be the same type, either both VLNC5s, VLNC6s, VLNC25s
or VLNC26s.
...........................................................................................................................................................................
Step 6
Identify the top left slot on the Rack-Mount Metropolis
®
DMXplore
shelf. See Figure 4-2, Rack-Mount Metropolis
®
DMXplore Shelf Front
View (page 4-7).
...........................................................................................................................................................................
Step 7
Holding the Main 2 circuit pack upright in your hand, turn the circuit
pack 90 degrees to the right and place the Main OLIU circuit pack into
the large, upper left hand slot of the Rack-Mount Metropolis
®
DMXplore shelf. Do NOT engage the circuit pack in the backplane
connector.
...........................................................................................................................................................................
Step 8
Check off the appropriate box in Appendix E, Installation Checklist.
End of Steps
10/100 T Fast Ethernet
Installation
Follow this procedure if you are installing a VLNC15 10/100 T Fast
Ethernet circuit pack.
Step 1
Remove the VLNC15 10/100 BaseT FE circuit pack from the packing
material.
Step 1
Identify the unequipped Function Group-C slot on the upper right-hand
side of the shelf. Refer to Figure 4-2, Rack-Mount Metropolis
®
DMXplore Shelf Front View (page 4-7) for details.
...........................................................................................................................................................................
Step 2
Holding the VLNC15 FE circuit pack upright in your hand, turn the
circuit pack 90 degrees to the right and place the circuit pack into the
Function Group-C slot. Rack-Mount Metropolis
®
DMXplore shelf. Do
NOT engage the circuit pack in the backplane connector.
Summary of Contents for Metropolis DMXplore
Page 8: ... C O N T E N T S v i i i 365 372 334 R2 0 Issue 4 November 2004 ...
Page 16: ... T A B L E S x v i 365 372 334 R2 0 Issue 4 Novmeber 2004 Glossary ...
Page 286: ... Backplane Pin Replacement Replacement Methods D 1 0 365 372 334 R2 0 Issue 4 November 2004 ...
Page 292: ... Installation Checklist Overview E 6 365 372 334 R2 0 Issue 4 November 2004 ...
Page 326: ... G L O S S A R Y G L 3 0 365 372 334 R2 0 Issue 4 November 2004 ...