Installation Tests
Clearing Alarms
...........................................................................................................................................................................................................................................................
6 - 7
365-372-334 R2.0
Issue 4, November 2004
............................................................................................................................................................................................................................................................
Clearing Alarms
Description
In order to clear standing alarms the Metropolis
®
DMXplore
synchronization will be provisioned as "Free Running". The DCC will
be disabled in order to prevent DCC alarms from being generated due
to the optical loopback on the main OLIUs.
Step 1
Use the scroll bar in the
Command Builder
window to scroll down to
the
set-syncn(free run)
command
...........................................................................................................................................................................
Step 2
Click on the
set-syncn(free run)
command.
Result:
The
set-sync:lt-dmxplore:all:ctag::frng;
command will
be displayed in the command window to the left of the
Send
button.
...........................................................................................................................................................................
Step 3
Click
Send
to issue the command.
Result:
The
Response Window
will display the command
followed by a
COMPLD
indication.
...........................................................................................................................................................................
Step 4
Use the scroll bar in the
Command Builder
window to scroll down to
the
ent-fecom
command.
...........................................................................................................................................................................
Step 5
Click on the
ent-fecom
command.
...........................................................................................................................................................................
Step 6
Under the
Parameters
section,
<FECOMAID>,
click on
dcc-m-1.
Summary of Contents for Metropolis DMXplore
Page 8: ... C O N T E N T S v i i i 365 372 334 R2 0 Issue 4 November 2004 ...
Page 16: ... T A B L E S x v i 365 372 334 R2 0 Issue 4 Novmeber 2004 Glossary ...
Page 286: ... Backplane Pin Replacement Replacement Methods D 1 0 365 372 334 R2 0 Issue 4 November 2004 ...
Page 292: ... Installation Checklist Overview E 6 365 372 334 R2 0 Issue 4 November 2004 ...
Page 326: ... G L O S S A R Y G L 3 0 365 372 334 R2 0 Issue 4 November 2004 ...