Operational Tests
Miscellaneous (Environmental) Discrete
Telemetry Test
7 - 1 6
365-372-334 R2.0
Issue 4, November 2004
...........................................................................................................................................................................
Step 6
Use the scroll bar in the
Command Builder
window to scroll down to
the
rtrv-alm-env
command.
...........................................................................................................................................................................
Step 7
Click on the
rtrv-alm-env
command.
...........................................................................................................................................................................
Step 8
Click
Send
to issue the command.
Result:
The Response Window will display the command followed
by a
COMPLD
indication as well as indicating the correct
environmental alarm has been activated.
...........................................................................................................................................................................
Step 9
Remove the short and verify that the minor (
MN/ABN
) alarm
indication on the SYSCTL clears.
...........................................................................................................................................................................
Step 10
Repeat Step 3 through Step 9 for each environmental input being used.
...........................................................................................................................................................................
Step 11
Check off the appropriate box in Appendix E, Installation Checklist.
End of Steps
...........................................................................................................................................................................
MDO Test Procedure
Step 1
Determine which environmental outputs are to be activated via the
Metropolis
®
DMXplore shelf.
...........................................................................................................................................................................
Step 2
Verify that the miscellaneous discrete cables are connected to the
MDO
connector block on the Access Panel. See Figure 1-16, Miscellaneous
Discrete Cable Connection (page 1-39)
...........................................................................................................................................................................
Step 3
Use the scroll bar in the
Command Builder
window to scroll down to
the
opr-ext-cont
command.
Summary of Contents for Metropolis DMXplore
Page 8: ... C O N T E N T S v i i i 365 372 334 R2 0 Issue 4 November 2004 ...
Page 16: ... T A B L E S x v i 365 372 334 R2 0 Issue 4 Novmeber 2004 Glossary ...
Page 286: ... Backplane Pin Replacement Replacement Methods D 1 0 365 372 334 R2 0 Issue 4 November 2004 ...
Page 292: ... Installation Checklist Overview E 6 365 372 334 R2 0 Issue 4 November 2004 ...
Page 326: ... G L O S S A R Y G L 3 0 365 372 334 R2 0 Issue 4 November 2004 ...