Operational Tests
Office Alarm Test
7 - 6
365-372-334 R2.0
Issue 4, November 2004
...........................................................................................................................................................................
Step 4
Under the
Parameters
section,
<rrSB>,
click on
NTFCNCDE={NA}.
Double click on
{NA}
and choose the MN.
Result:
A command similar to the following example will be
displayed in the command window to the left of the
Send
button.
Example:
ent-rr:lt-dmxplore:x-1-1:ctag:::NTFCNCDE=MN;
...........................................................................................................................................................................
Step 5
Change aid parameter in the command line from
x-1-1
to
x-all
.
Example:
ent-rr:lt-dmxplore:x-all:ctag:::NTFCNCDE=MN;
...........................................................................................................................................................................
Step 6
Click
Send
to issue the command.
Result:
The
Response Window
will display the command
followed by a
COMPLD
indication.
...........................................................................................................................................................................
Step 7
Connect the office alarm cables to
ALARM
termination block on the
access panel of the Metropolis
®
DMXplore shelf.
...........................................................................................................................................................................
Step 8
Introduce a valid DS1 or DS3 signal, then remove signal.
Requirement:
Activated office alarms:
MN/ABN
visual, MN/ABN
audible.
Important!
Alarms will not be activated until the alarm delay time
has passed. The default time is 2 seconds.
...........................................................................................................................................................................
Step 9
Press the
ACO/TST
push-button on the SYSCTL.
Result:
Activated office alarm:
MN/ABN
visual, the MN/ABN
audible alarm clears.
...........................................................................................................................................................................
Step 10
Reconnect valid DS1 or DS3 signal, and wait for alarms to clear.
Summary of Contents for Metropolis DMXplore
Page 8: ... C O N T E N T S v i i i 365 372 334 R2 0 Issue 4 November 2004 ...
Page 16: ... T A B L E S x v i 365 372 334 R2 0 Issue 4 Novmeber 2004 Glossary ...
Page 286: ... Backplane Pin Replacement Replacement Methods D 1 0 365 372 334 R2 0 Issue 4 November 2004 ...
Page 292: ... Installation Checklist Overview E 6 365 372 334 R2 0 Issue 4 November 2004 ...
Page 326: ... G L O S S A R Y G L 3 0 365 372 334 R2 0 Issue 4 November 2004 ...