36
LNC woodworking Machine Series Operation Manual
寶元數控
LNC Technology Co., Ltd.
Adsorption Function
4.3.
1. The system provides two types of adsorption, one is the partition adsorption control on the
worktable surface; the other is the adsorption control of the entire worktable, as shown in the
following diagram:
2. The adsorption related parameter setting is located in the system value in the user
parameters.
Parameter
No.
Parameter Content
8309
Maintenance time (ms) of vacuum destruction 1
8310
Maintenance time (ms) of vacuum destruction 2
3. The adsorption related M-code setting is located in the M-code setting in the user
parameters.
Parameter No.
M-code Content
Default
Value
9408
[M-code Setting] Adsorption 1
on
90
9409
[M-code Setting] Adsorption 1
off
91
9410
[M-code Setting] Adsorption 2
on
96
9411
[M-code Setting] Adsorption 2
off
97
9412
[M-code Setting] Vacuum pump
1 on
10
9413
[M-code Setting] Vacuum pump
1 off
11
9414
[M-code Setting] Vacuum pump
2 on
20