Block diagram:
PC-25
POL
The output level for the expected overload
Communication
address:
0232H
0233H
Initial value
0
Control mode
ALL
Unit
%
Configuration range
0 ~ 100
Data size
16bit
Data format
Dec
If the setting is between 0 and 100 and the continuous output load of the servo motor is above the set ratio (PC-
25), the warning signal for expected overload will be output (DO set to 10, OLW). Cancel the function if the
setting value is above 100.
+
Speed command
Feedback command
Absolute value taken
SPOK output ON
SPOK output OFF
Absolute value
below PC-23?