Lite-On Technology Corp.
Industrial Automation
121
PB-25
SPR
The ratio for the gain variation of the speed
control
Communication
address:
0132H
0133H
Initial value
100
Control mode
ALL
Unit
%
Configuration range
10 ~ 500
Data size
16bit
Data format
Dec
This is used to switch the change rate regarding the gain of the speed control based on the condition of gain
switch.
PB-26
KVI
The integral compensation for the speed control
Communication
address:
0134H
0135H
Initial value
50
Control mode
ALL
Unit
rad/s
Configuration range
0 ~ 1023
Data size
16bit
Data format
Dec
When the integral value of the speed control is increased, the position response is increased and the error
magnitude of the speed control is reduced. Vibration and noise occurs easily if the gain is set to an excessive
value.
PB-27
KVF
The feed forward gain for the speed control
Communication
address:
0136H
0137H
Initial value
0
Control mode
ALL
Unit
%
Configuration range
0 ~ 100
Data size
16bit
Data format
Dec
For smooth change of the speed control command, the increase in gain improves the magnitude of the following
error for the speed. For unsmooth change of the speed control command, the decrease in gain mitigates the
vibration of the mechanism during operation.