Lite-On Technology Corp.
Industrial Automation
61
4.2.
Panel operating process
1.
When the power supply of the drive is input, the display continues to display the monitoring mode (the
monitoring parameter set by the PD-21) first. The alarm code shows up first if there is any alarm.
2.
Press the MODE key to switch the parameter display → monitoring display → error display. The alarm
mode is omitted if there is no alarm.
3.
For any new alarm, it is possible to switch the current mode to the alarm mode instantly. Press the
MODE key to switch to other modes.
4.
In the monitoring display, switch the monitoring variable to press the UP or DOWN key. After selecting
the monitoring variable, press the SET key to confirm to enter the display.
5.
In the parameter display, press the SHIFT key to switch the group code. Press the UP/DOWN key to
change the last two character parameter codes.
6.
In the parameter display, press the SET key to enter the editing setting mode. The display shows the
setting value of the current parameter. Use the UP/DOWN key to modify the parameter value or press
the MODE key to exit the editing setting mode and return to the parameter mode.
Error display
Monitoring
display
Basic
parameter
I/O
configuration
parameters
Extended
parameter
Gain/filtering
parameter
AL.00
1
CD-P
FB-P
IGBT
PA-00
PA-01
PB-00
PB-01
PC-00
PC-01
PD-00
PD-01
00000
00007
Mode
Shift
Shift
Shift
Up or down
Up or down
Up or down
SET for displaying
the parameter
value
Storage parameter
setting
Shift for switching the
high and low order
digits
SET
Switching between the
decimal/hexadecimal
number system
Shift