Lite-On Technology Corp.
Industrial Automation
189
PD-29
VMR2
Ratio for MON2 analog monitoring
output
Communication
address:
033AH
033BH
Initial value
100
Control mode
ALL
Unit
%
Configuration range
0 ~ 100
Data size
16bit
Data format
Dec
PD-39
AOUT
Setting for the polarity of the pulse
output for the detector
Communication
address:
034AH
034BH
Initial value
Control mode
Unit
Configuration range
Data size
Data format
7.5.4.
Use of the electromagnetic brake
PC-21
BTOD
Turn-on delay time for the
electromagnetic brake
Communication
address:
022AH
022BH
Initial value
0
Control mode
ALL
Unit
ms
Configuration range
0 ~ 1000
Data size
16bit
Data format
Dec
Parameter function: It sets the time delayed from the the time servo is activated to the time
that the interlock signal of the electromagnetic brake (DO code 0x07, BREAK) is turned on.