19. Setting the GSG-AN-VM
19.1. Calculation of the spray liquid discharge
Calculate the liquid discharge based on the following formula:
Liquid
discharge in
l/min
Driving
speed
Row
spacing
Expended
quantity
Number of
Tunnel
=
(km/h)
x
(m)
x
l/ha
x
600
Sample calculation
based on the following data:
Required water quantity:
600
l/ha
Driving speed
6
km/h
Row spacing:
2
m
Number of tunnels
2
Calculation:
600 x 6 x 2 x 2
=
24 l/min
600
The calculated liquid discharge for the complete GSG-AN-VM is
in this case 24 l/min.
For the required quantity of plant protection agent for the intend-
ed purpose, please follow the instructions for the plant protection
agent.
The surface area is generally stated in hectares (ha).