Operating instruction
Saddle-mount fan unit with tank trailer GSG-AN-VM
35 - 72
011170-05-EN BA GSG-AN-VM / 2019-01-16
18.6. Checking liquid output at the GSG-AN-VM
General:
Check the liquid output once each year at the beginning of the
season, in the case of changes in the liquid circulation or after
replacing nozzles.
•
Before determining the liquid output, the
GSG-AN-VM
must be
equipped with the proper nozzles for the operating conditions.
•
Use attached nozzle chart for the
GSG-AN-VM
or that of a noz-
zle manufacturer.
•
Select nozzles based on the calculated driving speed, required
liquid output and pressure range between 5 and 12 bar.
•
Now check the liquid output at the
GSG-AN-VM.
Measurement:
Make the measurement using water only.
•
Fill the tank with water up to a clearly visible mark. The marking
should preferably be in the narrowest point in the filling mandrel,
since the small diameter there immediately shows small changes
in the liquid level.
This provides for a more accurate measurement and reduces the
time required for measuring.
•
After filling the tank with water, set the required pressure using
the buttons on the control box with the spray nozzles switched
on.
The pressure to be set is based on the calculated engine RPM
for the optimum driving speed.
•
Make sure that all lines in the system are filled with liquid. Air in
the system will result in an incorrect measurement.
If necessary, switch on the sprayers until liquid is spraying even-
ly out of the nozzles.