Operating instruction
Saddle-mount fan unit with tank trailer GSG-AN-VM
60 - 72
011170-05-EN BA GSG-AN-VM / 2019-01-16
Recycling injector:
•
After repair or cleaning, make
sure that the injector is re-
assembled correctly.
(Fig. 44)
Pay attention to the diameter
“d”, as there are different ver-
sions
– see also spare parts
list.
Fig. 44
•
Grease bearings of all fans
every 8 hours. Access to the
greasing nipple is from outside
the fan unit wall.
One nipple per bearing, overall
number of nipples depends on
fan unit wall height.