Operating instruction
Saddle-mount fan unit with tank trailer GSG-AN-VM
54 - 72
011170-05-EN BA GSG-AN-VM / 2019-01-16
•
Set the 3-way
(“1”) valve to the middle position “Clean suction
filter” (Fig. 32). This will shut-off the agent spraying circuit.
2-
way valve “2”
3-
way valve “1”
Fig. 32
•
Set 2-way valve
(“2”) to position “Machine cleaning” (Fig. 32).
The pump will bring fresh water from fresh water tank throughout
the spraying nozzles.
•
Set 2-
way valve (“3”) to posi-
tion “Machine cleaning” (Fig.
33).
Fig. 33
•
Shut-off Recycling procedure on control box.
This avoids, that cleaning liquid is pumped through recycling in-
jectors back to the spray liquid tank, thus thinning the liquid in
the spray liquid tank.
•
Switch on pump, water from fresh water tank is now cleaning all
fittings, filters close to the spraying nozzles and the nozzles
themselves.
•
The cleaning liquid must be disposed on agricultural / forested /
horticultural surface.