18.11. RPM fan setting
Two parameters determine the speed of the cross-flow fan as
well as the volume of produced air.
These are:
Oil volume coming from tractor side (l/min) as well as oil pres-
sure.
The following table gives you a rough idea about the dependen-
cies.
q
Tractor
output
(l / min.)
p
Pressure
(bar)
n
Fan setting
(rpm)
Air volume
at fan exit
(m³/h)
v
Air exit
speed
(m/s)
18
70
1120
500
11
20
85
1300
600
14.8
25
120
1600
720
17
Note:
Maximum allowable hydraulic pressure for the cross-flow fan is
120 bar. Higher pressure can result in hydraulic motor damage
of the fan drive.