Operating instruction
Saddle-mount fan unit with tank trailer GSG-AN-VM
64 - 72
011170-05-EN BA GSG-AN-VM / 2019-01-16
29. Storage of the machine
If the
GSG-AN-VM
will be no more used for a longer period, you
should perform the following steps:
•
Check the function of all moving parts and replace worn or dam-
aged parts.
•
Check valves and fittings.
•
Check to make sure that all bolts are tightened.
•
Check oil and grease levels.
•
Empty all tanks via the valves/drain plugs and clean using fresh
water.
•
Do not tightly close tanks during storage to prevent mold.
•
Store unused spray liquid in the containers provided until next
use.
•
Clean suction filter using fresh water.
•
To protect the cross-flow fan unit from damage during the winter
months, the unit must be filled with an antifreeze agent mixed
with water after cleaning all parts. (The proportion of anti-freeze
agent to water is based on the expected temperatures.)
Afterwards, rinse all elements of the liquid circulation by means
of the pump; actuate all valves / shut-off gates and nozzles sev-
eral times to ensure that all parts come into contact with the anti-
freeze solution, so they are coated with a protective film.
The anti-freeze solution should remain in the spray unit through-
out the winter; do not drain until there is no longer a danger of
frost in the spring.
The anti-freeze agent prevents corrosion on the pump parts and
aging of seals.
The anti-freeze can be re-used the following winter.
Summary of Contents for GSG-AN-VM
Page 72: ...Design mail bauer ib com...