PIPEFAB™ WELDING SYSTEM
OPERATION
B-36
START OPTIONS
The Start Op
�
ons available depend upon the process and weld mode selected.
TABLE B.3
PROCESS
START
OPTION
EFFECT /
RANGE
DESCRIPTION
STICK
---
---
---
ALL MIG
AND
FCAW
PREFLOW
TIME
0 – 60.0
SECONDS
RUN-IN WFS
AUTO, OFF,
50-150
IN/MIN TO
WELD WFS
RUN-IN SETS THE WIRE FEED SPEED FROM THE TIME
THE TRIGGER IS PULLED UNTIL AN ARC IS
ESTABLISHED OR 2.5 SECONDS.
USE RUN-IN FOR SOFTER ARC STARTS.
START TIME,
WFS AND
VOLTS
0 – 10.0
SECONDS
THE START PROCEDURE CONTROLS THE WFS AND
VOLTS FOR A SPECIFIED TIME AT THE BEGINNING OF
THE WELD. DURING THE START TIME, THE MACHINE
WILL RAMP UP OR DOWN FROM THE START
PROCEDURE TO THE PRESET WELDING PROCEDURE.
TIG
PREFLOW
TIME
0 – 60.0
SECONDS
---
Summary of Contents for PIPEFAB CE