PIP
E
FAB™ WELDING SYSTEM
INSTALLATION
A-
2
SAFETY PRECAUTIONS
Read this entire installation section before operating machine.
SELECT SUITABLE LOCATION
The PipeFab™ will operate in harsh environments. Even so, it is important that simple preventative
measures are followed in order to assure long life and reliable operation.
•
The machine must be located where there is free circulation of clean air such that air movement
in the front and back, out the sides and bottom will not be restricted.
•
Dirt and dust that can be drawn into the machine should be kept to a minimum. The use of air
filters on the air intake is not recommended because normal airflow may be restricted. Failure
to observe these precautions can result in excessive operating temperatures and nuisance
shutdown.
•
Keep machine dry. Shelter from rain and snow. Do not place on wet ground or in puddles.
•
Do not mount the PipeFab™ over combustible surfaces. Where there is a combustible surface
directly under stationary or fixed electrical equipment, that surface shall be covered with a steel
plate at least .060” (1.6mm) thick, which shall extend not less than 5.90” (150mm) beyond the
equipment on all sides.
•
The PipeFab™ feeder is rated IP2X and is suitable for indoor use. For best wire feeding
performance, place the PipeFab™ Feeder on a stable and dry surface.
•
Do not submerge the feeder.
This equipment is for industrial use only and it is not intended for use in residential locations where the
electrical power is provided by the public low-voltage supply system. There can be potential difficulties
in residential locations due to conducted as well as radiated radio-frequency disturbances. The EMC or
RF classification of this equipment is Class A.
LIFTING
Lift the machine by the lift bail only. The lift bail is designed to lift the power source only. Do not
attempt to lift the power source with feeder or accessories attached to it.
When suspending a wire feeder, insulate the hanging device from the wire feeder enclosure.
STACKING
The PipeFab™ cannot be stacked.
TILTING
Place the machine directly on a secure, level surface or on a recommended undercarriage. The machine
may topple over if this procedure is not followed.
For bench models, do not angle spindle for the wire spool or coil more than 15 degrees downward.
Summary of Contents for PIPEFAB CE
Page 18: ...PIPEFAB WELDING SYSTEM INSTALLATION A 3 FIGURE A 1 ...
Page 97: ......