PIPEFAB™ WELDING SYSTEM
OPERATION
B-11
TIG HOME SCREEN
FIGURE B.8
1. Menu Bar - Use the Menu knob to scroll through the op
�
ons along the bo
�
om of the screen.
Press the knob to select the highlighted op
�
on.
2. Current Se
�
ng - Sets the desired current, use le
�
knob to adjust.
3. Start Type Selec
�
on – Touch Start, HF.
4. Post-Flow Time – Time that the shielding gas con
�
nues to
fl
ow a
�
er the arc has been
terminated. Only displayed when set to a non-zero value.
5. Pre-Flow Time - Time that the shielding gas con
�
nues to
fl
ow before the arc has been started.
Only displayed when set to a non-zero value.
6. Output Indicator – Output will be on in Touch Start mode without a remote. Output will be o
ff
un
�l
triggered when a remote is connected. NOTE: HF mode requires a remote to be
connected.