108
Indoor Unit
Specifications
1. Specifications
1.1.1 Cooling Only
Cooling Only (50Hz)
1.1 50Hz
Model
Unit
W
Cooling Capacity
kcal/h
Btu/h
W
Heating Capacity
kcal/h
Btu/h
Dimensions (W*H*D) Body
mm
inch
Coil
Rows x Columns x FPI
Face Area
m
2
Type
Motor Output
W
Running Current
A
Fan
Air Flow Rate(H/M/L)
cmm
cfm
Drive
Speed control
Temperature Control
Sound Absorbing Thermal Insulation Material
Air Filter
Safety Device
Liquid Side
mm(inch)
Pipe Connections Gas Side
mm(inch)
Drain Pipe(ID)
mm
Net Weight
kg(lbs)
Noise Level(Sound Press, 1.5m, H/M/L)
dBA±3
Power Supply
Ø / V / Hz
Refrigerant Control
Power cable
mm
2
Transmission cable
mm
2
Panel Color
Stuffing Quantity Without S/parts
20/40ft
LRNV076SRA(L)0 LRNV096SRA(L)0 LRNV126SRA(L)0 LRNV186STA(L)0
2,100
2,600
3,500
5,300
1,806
2,235
3,009
4,557
7,165
8,871
11,942
18,084
-
-
-
-
-
-
-
-
-
-
-
-
900*285*156
900*285*156
900*285*156
1090*314*172
35.4*11.2*6.1
35.4*11.2*6.1
35.4*11.2*6.1
42.9*12.4*6.8
2*12*20
2*12*20
2*12*20
2*13*20
0.13 0.13 0.13 0.23
Cross Flow Fan
Cross Flow Fan
Cross Flow Fan
Cross Flow Fan
15
15
15
25
0.20 0.20 0.20 0.30
5.6/5/4.6
7/ 6.5 /6
9.5/ 9/8.5
12/10.5/10.3
198/177/162.5
247/230/212
336/318/300
424/371/364
Direct
Direct
Direct
Direct
Phase Control
Phase Control
Phase Control
Phase Control
Microprocessor, Thermostat for cooling Microprocessor, Thermostat for cooling Microprocessor, Thermostat for cooling Microprocessor, Thermostat for cooling
Foamed polystrene
Foamed polystrene
Foamed polystrene
Foamed polystrene
Resin Net(washable)
Resin Net(washable)
Resin Net(washable) Resin Net(washable)
Fuse
Fuse
Fuse
Fuse
Ø6.35(1/4)
Ø6.35(1/4)
Ø6.35(1/4)
Ø9.52(3/8)
Ø12.7(1/2)
Ø12.7(1/2)
Ø12.7(1/2)
Ø15.88(5/8)
20
20
20
20
7(15.4)
7(15.4)
7(15.4)
12(26.5)
33/30/27
34/31/28
36/33/30
40/37/34
1 / 220 ~ 240 / 50
1, 220 ~ 240, 50
1 / 220 ~ 240 / 50 1 / 220 ~ 240 / 50
LEV
LEV
LEV
LEV
CV2.0 X 3C
CV2.0 X 3C
CV2.0 X 3C
CV2.0 X 3C
CVV-SB 1.25 X 2C CVV-SB 1.25 X 2C
CVV-SB 1.25 X 2C CVV-SB 1.25 X 2C
White
White
White
White
340/720
340/720
340/720
270/540
Notes:-
1. Capacities are based on the following conditions:
Cooling • Indoor temp. 27°C[80.6°F]DB/ 19°C[66.2°F]WB
• Outdoor temp. 35°C[95°F]DB/ 24°C[75.2°F]WB
• Interconnecting Piping Length 7.5m
• Level Difference of Zero
2. Capacities are net capacities
3. Due to our policy of innovation some specifications may be changed without notification
4. L.E.V.: Linear Expansion Valve
Conversion Formula
Kcal/h= kW x 860
Btu/h = kW x 3414
cfm = m
3
/min x 35.3
Summary of Contents for multi V PLUS
Page 21: ...Service Manual 21 Indoor Unit Indoor Units ...
Page 74: ...74 Indoor Unit ...
Page 86: ...86 Indoor Unit ...
Page 142: ...142 Indoor Unit ...
Page 160: ...160 Indoor Unit ...
Page 179: ...Service Manual 179 Outdoor unit ...
Page 239: ...Service Manual 239 Wiring Diagrams 5 8 60Hz 220V Main Outdoor Unit 8HP 10HP 12HP ...
Page 245: ...Service Manual 245 Trouble shooting guide ...
Page 296: ...296 Trouble Shooting Guide ...
Page 297: ...Service Manual 297 Appendix ...
Page 303: ...Service Manual 303 Exploded View Replacement Parts List ...