Multi V 5
6. Electric Characteristics
88
Outdoor Units
■
50Hz
Model
Unit
Power Supply
COMP
OFM
Hz
Volts
Voltage-range
MCA
TOCA
MFA
MSC
RLA(Cooling)
RLA(Heating)
kW
FLA
8 HP
50
380-415
Min.:342, Max.:456
18.2
20.0
20
4.3
4.5
5.3
1.20
2.5
10 HP
50
380-415
Min.:342, Max.:456
25.5
28.0
32
5.9
6.0
7.2
1.20
2.5
12 HP
50
380-415
Min.:342, Max.:456
25.5
28.0
32
5.9
8.7
11.0
1.20
2.5
14 HP
50
380-415
Min.:342, Max.:456
25.5
28.0
32
5.9
11.2
13.4
1.80
2.5
16 HP
50
380-415
Min.:342, Max.:456
25.5
28.0
32
5.9
14.5
17.7
1.80
2.5
18 HP
50
380-415
Min.:342, Max.:456
42.7
47.0
50
10.2
13.6
17.0
1.80
2.5
20 HP
50
380-415
Min.:342, Max.:456
44.5
49.0
50
10.2
16.3
21.5
1.80
2.5
22 HP
50
380-415
Min.:342, Max.:456
45.5
50.0
50
10.2
20.6
24.9
1.80
2.5
24 HP
50
380-415
Min.:342, Max.:456
49.1
54.0
63
11.8
23.5
28.2
1.80
2.5
26 HP
50
380-415
Min.:342, Max.:456
49.1
54.0
63
11.8
27.0
28.8
1.80
2.5
22’ HP
50
380-415
Min.:342, Max.:456
50.9
56.0
63
11.8
14.7
18.2
2.40
5.0
24’ HP
50
380-415
Min.:342, Max.:456
50.9
56.0
63
11.8
17.3
22.0
2.40
5.0
26’ HP
50
380-415
Min.:342, Max.:456
50.9
56.0
63
11.8
19.9
24.4
2.40
5.0
28 HP
50
380-415
Min.:342, Max.:456
50.9
56.0
63
11.8
23.2
28.7
3.00
5.0
30 HP
50
380-415
Min.:342, Max.:456
68.2
75.0
80
16.1
22.3
28.0
3.00
5.0
32 HP
50
380-415
Min.:342, Max.:456
70.0
77.0
80
16.1
25.0
32.5
3.00
5.0
34 HP
50
380-415
Min.:342, Max.:456
69.6
78.0
80
16.1
29.3
35.9
3.00
5.0
36 HP
50
380-415
Min.:342, Max.:456
71.9
82.0
80
17.7
32.2
39.2
3.00
5.0
38 HP
50
380-415
Min.:342, Max.:456
72.6
82.0
100
17.7
34.7
41.6
3.60
5.0
40 HP
50
380-415
Min.:342, Max.:456
74.5
82.0
100
17.7
38.0
46.0
3.60
5.0
42 HP
50
380-415
Min.:342, Max.:456
91.0
101.0
100
22.0
37.1
45.2
3.60
5.0
44 HP
50
380-415
Min.:342, Max.:456
92.0
103.0
100
22.0
39.8
49.7
3.60
5.0
46 HP
50
380-415
Min.:342, Max.:456
91.2
104.0
100
22.0
44.1
53.1
3.60
5.0
48 HP
50
380-415
Min.:342, Max.:456
98.2
108.0
125
23.6
47.0
56.4
3.60
5.0
50 HP
50
380-415
Min.:342, Max.:456
100.0
110.0
125
23.6
43.4
52.6
4.80
7.5
52 HP
50
380-415
Min.:342, Max.:456
100.0
110.0
125
23.6
46.7
56.9
4.80
7.5
54 HP
50
380-415
Min.:342, Max.:456
113.2
129.0
125
27.9
45.7
56.2
4.80
7.5
56 HP
50
380-415
Min.:342, Max.:456
115.9
131.0
125
27.9
48.5
60.7
4.80
7.5
58 HP
50
380-415
Min.:342, Max.:456
120.0
132.0
150
27.9
52.8
64.1
4.80
7.5
60 HP
50
380-415
Min.:342, Max.:456
123.6
136.0
150
29.5
55.7
67.4
4.80
7.5
62 HP
50
380-415
Min.:342, Max.:456
123.6
136.0
150
29.5
58.2
69.8
5.40
7.5
64 HP
50
380-415
Min.:342, Max.:456
123.6
136.0
150
29.5
61.5
74.2
5.40
7.5
66 HP
50
380-415
Min.:342, Max.:456
134.8
155.0
150
33.8
60.5
73.4
5.40
7.5
68 HP
50
380-415
Min.:342, Max.:456
136.5
157.0
150
33.8
63.3
77.9
5.40
7.5
70 HP
50
380-415
Min.:342, Max.:456
136.2
158.0
150
33.8
67.6
81.3
5.40
7.5
72 HP
50
380-415
Min.:342, Max.:456
147.3
162.0
175
35.4
70.5
84.6
5.40
7.5
74 HP
50
380-415
Min.:342, Max.:456
149.1
164.0
175
35.4
66.9
80.8
6.60
10.0
76 HP
50
380-415
Min.:342, Max.:456
149.1
164.0
175
35.4
70.2
85.2
6.60
10.0
78 HP
50
380-415
Min.:342, Max.:456
166.4
183.0
200
39.7
69.2
84.4
6.60
10.0
80 HP
50
380-415
Min.:342, Max.:456
168.2
185.0
200
39.7
72.0
88.9
6.60
10.0
82 HP
50
380-415
Min.:342, Max.:456
169.1
186.0
200
39.7
76.3
92.3
6.60
10.0
84 HP
50
380-415
Min.:342, Max.:456
172.7
190.0
200
41.3
79.2
95.6
6.60
10.0
Note
1. Voltage supplied to the unit terminals should be within the minimum and maximum
range.
2. Maximum allowable voltage unbalance between phase is 2%.
3. MSC means the Max. current during the starting of compressor.
4. MSC and RLA are measured as the compressor only test condition.
5. OFM are measured as the outdoor unit test condition.
6. TOCA means the total over current value of each outdoor unit.
7. Select the wire size based on the larger value among MCA or TOCA.
8. MFA is recommended fuse amps.
9. TOCA is minimum required amperes for selecting the circuit breaker and ground fault
circuit interrupter. Please select the circuit breaker size equal or greater than TOCA.
All installation site must require attachment of an earth leakage breaker.[Circuit breaker
type is ELCB (Earth Leakage Circuit Breaker)].
10.Select the electrical equipment of combination unit according to the electrical
characteristics of individual unit.
’ : 2 unit combination models
Symbols
MCA :
Minimum Circuit Amperes (A)
TOCA :
Total Over Current Amperes (A)
MFA :
Maximum Fuse Amperes (A)
MSC :
Maximum Starting Current (A)
RLA :
Rated Load Amperes (A)
OFM :
Outdoor Fan Motor
kW :
Fan Motor rated output (kW)
FLA :
Full Load Amperes (A)
Summary of Contents for ARUM080LTE5
Page 1: ...Heat Recovery Heat Pump R410A 50Hz 60Hz 0CVV0 01E Replaces 0CVV0 01D P No MFL67474071 ...
Page 85: ...78 Multi V 5 Outdoor Units 4 Wiring Diagrams 4 1 8 10 12 HP UXA 1 Comp ...
Page 86: ...4 Wiring Diagrams 79 Multi V 5 Outdoor Units 4 2 14 16 HP UXB 1 Comp ...
Page 87: ...Multi V 5 4 Wiring Diagrams 80 Outdoor Units 4 3 18 20 22 24 26HP UXB 2 Comp ...
Page 766: ...Special Guide Multi V 5 1 Cautions for Refrigerant Leaks 2 Guide for installing at seaside ...