Multi V 5
1. Specifications
16
Outdoor Units
HP
30
32
Model Name
Combination Unit
ARUM300LTE5
ARUM320LTE5
Independent Unit
ARUM180LTE5
ARUM200LTE5
ARUM120LTE5
ARUM120LTE5
Capacity
Cooling
kW
84.0
89.6
Btu/h
286,600
305,700
Heating
kW
94.5
100.8
Btu/h
322,400
343,900
Input
Cooling
kW
16.68
18.35
Heating
kW
20.20
22.95
EER
5.04
4.89
COP
4.68
4.39
Exterior
Color
Morning Gray / Dawn Gray
Morning Gray / Dawn Gray
RAL (Classic)
RAL 7030 / RAL 7037
RAL 7030 / RAL 7037
Heat Exchanger
Wide Louver Plus
Wide Louver Plus
Compressor
Type
Hermetically Sealed Scroll
Hermetically Sealed Scroll
Piston Displacement
cm
3
/rev
(62.1 × 2) + (43.8 × 1)
(62.1 × 2) + (43.8 × 1)
Number of Revolution
rev/min
3,600 × 3
3,600 × 3
Motor Output x Number
W x No.
(5,300 × 2) + (4,200 × 1)
(5,300 × 2) + (4,200 × 1)
Starting Method
Inverter
Inverter
Oil Type
FW68D(PVE)
FW68D(PVE)
Fan
Type
Propeller fan
Propeller fan
Motor Output x Number
W
(900 × 2) + (1,200 × 1)
(900 × 2) + (1,200 × 1)
Air Flow Rate(High)
m
3
/min
(320 × 1) + (240 × 1)
(320 × 1) + (240 × 1)
ft
3
/min
(11,301 × 1) + (8,476 × 1)
(11,301 × 1) + (8,476 × 1)
External Static Pressure (Max, Pa)
80
80
Drive
DC INVERTER
DC INVERTER
Discharge
Side / Top
TOP
TOP
Pipe
Connections
#1
Liquid
mm(inch)
19.05(3/4)
19.05(3/4)
Low Pressure Gas
mm(inch)
34.9(1-3/8)
34.9(1-3/8)
High Pressure Gas
mm(inch)
28.58(1-1/8)
28.58(1-1/8)
Pipe
Connections
#2
Liquid
mm(inch)
19.05(3/4)
19.05(3/4)
Gas
mm(inch)
34.9(1-3/8)
34.9(1-3/8)
Dimensions(W x H x D)
mm
(1,240 × 1,690 × 760) × 1 + (930 × 1,690
× 760) × 1
(1,240 × 1,690 × 760) × 1 + (930 × 1,690
× 760) × 1
inch
(48-13/16 × 66-17/32 × 29-29/32) × 1 +
(36-5/8 × 66-17/32 × 29-29/32) × 1
(48-13/16 × 66-17/32 × 29-29/32) × 1 +
(36-5/8 × 66-17/32 × 29-29/32) × 1
Net Weight
kg
(300 × 1) + (215 × 1)
(300 × 1) + (215 × 1)
lbs
(661 × 1) + (474 × 1)
(661 × 1) + (474 × 1)
Sound
Pressure Level
Cooling
dB(A)
63.1
63.8
Heating
dB(A)
64.1
65.8
Sound Power
Level
Cooling
dB(A)
86.0
86.8
Heating
dB(A)
87.0
87.8
Note
1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics” chapter should be considered for electrical
work and design. Especially the power cable and circuit breaker should be selected in accordance with that.
3. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard.
Sound power level is measured on the rated condition in the semi-anechoic rooms by ISO 9614 standard.
Therefore, these values can be increased owing to ambient conditions during operation.
4. Sound values of combination model are calculated values based on sound results of independent models.
Sound values can be increased owing to ambient or installation conditions during operation.
Sound values of system [dB(A)] = 10*log [10^(A1/10)+ ... +10^(An/10)] , A1~An means sound values of independent models.
5. Performances are in accordance with ISO 15042.
• Interconnected Pipe Length is 7.5m and difference of Elevation (Outdoor ~ Indoor Unit) is 0m.
6. *** : The number in parentheses means maximum connectable indoor units in accordance with outdoor units combination (160~200%).
The recommended ratio is 130%.
7. This product contains Fluorinated greenhouse gases.(R410A, GWP(Global warming potential) = 2,087.5)
8. #1 : Heat Recovery system, #2 : Heat Pump system
Summary of Contents for ARUM080LTE5
Page 1: ...Heat Recovery Heat Pump R410A 50Hz 60Hz 0CVV0 01E Replaces 0CVV0 01D P No MFL67474071 ...
Page 85: ...78 Multi V 5 Outdoor Units 4 Wiring Diagrams 4 1 8 10 12 HP UXA 1 Comp ...
Page 86: ...4 Wiring Diagrams 79 Multi V 5 Outdoor Units 4 2 14 16 HP UXB 1 Comp ...
Page 87: ...Multi V 5 4 Wiring Diagrams 80 Outdoor Units 4 3 18 20 22 24 26HP UXB 2 Comp ...
Page 766: ...Special Guide Multi V 5 1 Cautions for Refrigerant Leaks 2 Guide for installing at seaside ...