Duplex Top Margin
This setting controls the offset between the first scan line on the front of the duplex page and the first scan line on the
back of the page. Therefore, be sure to set the top margin in REGISTRATION before setting the duplex top margin. See
To set the Duplex Top Margin
1
Select
DUPLEX TESTS
from Diag Menu, and press
Select
.
2
Select
Quick Test
, and press
Select
.
3
Select
Single
, and press
Select
.
4
Hold the page to the light to see whether the top margin of the back aligns with the top margin of the front.
5
Select
Top Margin
from DUPLEX TESTS.
6
Use
Left
or
Right
to select the margin setting you need to change.
•
Each increment shifts the duplex top margin by 1/100 of an inch.
•
The Top Margin (duplex) range is -50 to +50, and the default value is 0.
•
An increase in the value moves the backside top margin down and widens the top margin. A decrease moves
the top margin upward and narrows the top margin.
7
Press
Select
to save the new value.
8
Print the Quick Test (duplex) again (steps 1–4) to verify the adjustment. Repeat if necessary.
Duplex Left Margin
This setting shifts the image on the back of the duplex sheet to the left or right to correctly position it on the page.
Therefore, be sure to set the top margin in REGISTRATION before setting the duplex top margin. See
To set the Duplex Left Margin
1
Select
DUPLEX TESTS
from Diag Menu, and press
Select
.
2
Select
Quick Test
, and press
Select
.
3
Select
Single
, and press
Select
.
4
Hold the page to the light to see whether the top margin of the back aligns with the top margin of the front.
5
Select
Left Margin
from DUPLEX TESTS.
6
Use
Left
or
Right
to select the margin setting you need to change.
•
Each increment shifts the duplex left margin by 4 pixels at 500 dpi (0.0067 inches or 0.1693 mm).
•
The Left Margin (duplex) range is -25 to +25, and the default value is 0.
•
An increase in the value moves the backside left margin to the right, and widens the left margin. A decrease
moves the backside left margin to the left, and narrows the left margin.
7
Press
Select
to save the new value.
8
Print the Quick Test (duplex) again (steps 1–4) to verify the adjustment. Repeat if necessary.
7527
Service menus
202
Summary of Contents for XC2132
Page 18: ...7527 18 ...
Page 22: ...7527 22 ...
Page 34: ...7527 34 ...
Page 54: ...2 Open the top door 7527 Diagnostic information 54 ...
Page 184: ...7527 184 ...
Page 226: ...7527 226 ...
Page 314: ...5 Disconnect the belt C 6 Disconnect the fan and remove 7527 Repair information 314 ...
Page 345: ...Component locations Controller board CX310 models 7527 Component locations 345 ...
Page 346: ...CX410 models 7527 Component locations 346 ...
Page 352: ...7527 352 ...
Page 359: ...7527 359 ...
Page 361: ...Assembly 1 Covers 7527 Parts catalog 361 ...
Page 363: ...Assembly 2 Scanner 7527 Parts catalog 363 ...
Page 365: ...Assembly 3 Paperpath 7527 Parts catalog 365 ...
Page 368: ...7527 Parts catalog 368 ...
Page 369: ...Assembly 4 Operator panels 7527 Parts catalog 369 ...
Page 372: ...7527 Parts catalog 372 ...
Page 373: ...Assembly 5 Electronics 7527 Parts catalog 373 ...
Page 376: ...7527 Parts catalog 376 ...
Page 377: ...Assembly 6 Cables and sensors 7527 Parts catalog 377 ...
Page 379: ...Assembly 7 Media drawers and trays 7527 Parts catalog 379 ...
Page 382: ...7527 382 ...
Page 390: ...7527 390 ...
Page 404: ...7527 404 ...
Page 422: ...7527 Part number index 422 ...
Page 428: ...7527 Part name index 428 ...